Research on Optimizing Reactive Power Support Capability of Variable-Speed Pumped Storage Units

This paper focuses on the reactive power support issue during low-voltage ride-through (LVRT) in variable-speed pumped storage units. Building upon the relevant standards for wind turbine reactive power support, an optimized reactive power support strategy is proposed. This strategy maximizes the unit's reactive current output capability during LVRT by fully utilizing the capacity limits of the rotor-side converter (RSC). Meanwhile, it maintains certain active current output under specific operating conditions, facilitating rapid active power recovery after fault clearance. To validate the proposed control strategy, a 300MW unit simulation model was developed on the Real-Time Digital Simulator (RTDS) platform. The simulation results indicate that the control strategy proposed in this paper can improve the reactive current support capacity by about 10% compared with the traditional control in the LVRT process, and can maintain a certain active output, which has certain economyThe simulation results confirm the feasibility of the control approach.

Authors

Institutions

Publication Details

Published
2025-06-20
DOI
https://doi.org/10.1109/icesep66633.2025.11155236
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Optimizing Reactive Power Support Capability of Variable-Speed Pumped Storage Units

Shu Wang, Shanying Li, Yingjie Chen, Yian Yan et al.
Power Systems and Renewable Energy
article

Research on Optimizing Reactive Power Support Capability of Variable-Speed Pumped Storage Units

Shu Wang, Shanying Li, Yingjie Chen, Yian Yan, Weifu Lu
article en

Abstract

This paper focuses on the reactive power support issue during low-voltage ride-through (LVRT) in variable-speed pumped storage units. Building upon the relevant standards for wind turbine reactive power support, an optimized reactive power support strategy is proposed. This strategy maximizes the unit's reactive current output capability during LVRT by fully utilizing the capacity limits of the rotor-side converter (RSC). Meanwhile, it maintains certain active current output under specific operating conditions, facilitating rapid active power recovery after fault clearance. To validate the proposed control strategy, a 300MW unit simulation model was developed on the Real-Time Digital Simulator (RTDS) platform. The simulation results indicate that the control strategy proposed in this paper can improve the reactive current support capacity by about 10% compared with the traditional control in the LVRT process, and can maintain a certain active output, which has certain economyThe simulation results confirm the feasibility of the control approach.

Electric Power Research Institute (US), State Grid Corporation of China (China) (CN)
Openalex Percentile: Top 74%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.