A high-precision onboard radiometric calibration method based on cooperative light sources

Traditional radiometric calibration methods for spaceborne optical remote sensors rely on ground calibration fields, natural light sources such as the moon or stars, and onboard calibration mechanisms. These methods suffer from problems such as short calibration time windows, spatial-temporal inconsistencies during the calibration process, and limited calibration frequencies. This paper innovatively proposes an on-orbit real-time radiometric calibration method based on a cooperative light source in the very low Earth orbit (300 km). By constructing a cooperative satellite system equipped with a tunable laser source, an active reference light source with precise spectral radiation characteristics is established. Moreover, the advantages of the low Earth orbit significantly reduce the effects of aerosol scattering and water vapor absorption. A spatio-temporal synchronization model between the light source and the remote sensing satellite is established, and key indicators such as the light source power and tracking and pointing accuracy are quantitatively analyzed through simulations. The cooperative light source system can support the remote sensing satellite to complete real-time calibration within minutes at any transit time period by dynamically modulating the output light intensity. Under typical Earth observation scenarios, the error of radiometric reference transfer is less than 3%. This method provides all-weather autonomous calibration capabilities for high-frequency quantitative applications such as agricultural dynamic monitoring and disaster emergency remote sensing. It significantly improves the confidence level of surface parameter inversion and has the potential for engineering applications.

Authors

Institutions

Publication Details

Published
2025-09-15
DOI
https://doi.org/10.1117/12.3074483
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A high-precision onboard radiometric calibration method based on cooperative light sources

Gang Yuan, Guowei Yu, R. M. Zheng, Zhentao Yu
Calibration and Measurement Techniques
article

A high-precision onboard radiometric calibration method based on cooperative light sources

Gang Yuan, Guowei Yu, R. M. Zheng, Zhentao Yu
article en

Abstract

Traditional radiometric calibration methods for spaceborne optical remote sensors rely on ground calibration fields, natural light sources such as the moon or stars, and onboard calibration mechanisms. These methods suffer from problems such as short calibration time windows, spatial-temporal inconsistencies during the calibration process, and limited calibration frequencies. This paper innovatively proposes an on-orbit real-time radiometric calibration method based on a cooperative light source in the very low Earth orbit (300 km). By constructing a cooperative satellite system equipped with a tunable laser source, an active reference light source with precise spectral radiation characteristics is established. Moreover, the advantages of the low Earth orbit significantly reduce the effects of aerosol scattering and water vapor absorption. A spatio-temporal synchronization model between the light source and the remote sensing satellite is established, and key indicators such as the light source power and tracking and pointing accuracy are quantitatively analyzed through simulations. The cooperative light source system can support the remote sensing satellite to complete real-time calibration within minutes at any transit time period by dynamically modulating the output light intensity. Under typical Earth observation scenarios, the error of radiometric reference transfer is less than 3%. This method provides all-weather autonomous calibration capabilities for high-frequency quantitative applications such as agricultural dynamic monitoring and disaster emergency remote sensing. It significantly improves the confidence level of surface parameter inversion and has the potential for engineering applications.

Armed Forces Institute of Pathology (PK)
Openalex Percentile: Top 67%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.