Personalized pulse wave propagation modeling to improve vasopressor dosing management in patients with severe traumatic brain injury

This study investigates whether examining the shape of arterial pulse waves and fitting to them a physiology-based mathematical model of pulse wave propagation can provide additional insights into the state of the cardiovascular system in patients with severe traumatic brain injury (sTBI), potentially enhancing vasopressor dosing strategies. We conducted a longitudinal study on 25 sTBI patients in an intensive care unit. Arterial pulse waves were recorded non-invasively from wrists and ankles using an oscillometric method and were used to inform a 0-1D model of the arterial blood flow dynamics. Model-estimated, patient-specific cardiovascular parameters were then used in a statistical model to predict changes in the administered dose of vasopressor (norepinephrine) in the next 24 hours. The model fits to the recorded pulse waves were satisfactory, with the coefficients of determination ([Formula: see text]) of approximately 0.9 and the differences between the measured and model-estimated mean arterial pressure of 0.1 ± 1.0 mmHg ([Formula: see text]=0.99). Except for a few patients, we found no clear association between the model-estimated parameters and norepinephrine dose at the time of pulse wave recording. Nevertheless, our predictive model achieved a balanced accuracy of 0.85 when trained and tested on the entire dataset and 0.76 when using the leave-one-out cross-validation, with 8 misclassifications among the total of 77 observations. Thus, despite the known inter-patient variability of hemodynamic response to vasopressors, the proposed method allowed predicting the direction of norepinephrine dose changes in the next 24 hours with satisfactory accuracy. Subject to further studies and extensive validation, our approach could inform a decision-support tool for optimizing vasopressor dosing on a per-patient basis.

Authors

Institutions

Publication Details

Journal
PLoS Computational Biology
Published
2025-09-15
DOI
https://doi.org/10.1371/journal.pcbi.1013501
Primary Topic
Cardiac Arrest and Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Personalized pulse wave propagation modeling to improve vasopressor dosing management in patients with severe traumatic brain injury

Wojciech Dąbrowski, Wolos Kamil, Dorota Siwicka-Gieroba, Małgorzata Dębowska et al.
PLoS Computational Biology
Cardiac Arrest and Resuscitation
article

Personalized pulse wave propagation modeling to improve vasopressor dosing management in patients with severe traumatic brain injury

Wojciech Dąbrowski, Wolos Kamil, Dorota Siwicka-Gieroba, Małgorzata Dębowska, Jan Poleszczuk, Leszek Pstras, Urszula Białończyk
article en

Abstract

This study investigates whether examining the shape of arterial pulse waves and fitting to them a physiology-based mathematical model of pulse wave propagation can provide additional insights into the state of the cardiovascular system in patients with severe traumatic brain injury (sTBI), potentially enhancing vasopressor dosing strategies. We conducted a longitudinal study on 25 sTBI patients in an intensive care unit. Arterial pulse waves were recorded non-invasively from wrists and ankles using an oscillometric method and were used to inform a 0-1D model of the arterial blood flow dynamics. Model-estimated, patient-specific cardiovascular parameters were then used in a statistical model to predict changes in the administered dose of vasopressor (norepinephrine) in the next 24 hours. The model fits to the recorded pulse waves were satisfactory, with the coefficients of determination ([Formula: see text]) of approximately 0.9 and the differences between the measured and model-estimated mean arterial pressure of 0.1 ± 1.0 mmHg ([Formula: see text]=0.99). Except for a few patients, we found no clear association between the model-estimated parameters and norepinephrine dose at the time of pulse wave recording. Nevertheless, our predictive model achieved a balanced accuracy of 0.85 when trained and tested on the entire dataset and 0.76 when using the leave-one-out cross-validation, with 8 misclassifications among the total of 77 observations. Thus, despite the known inter-patient variability of hemodynamic response to vasopressors, the proposed method allowed predicting the direction of norepinephrine dose changes in the next 24 hours with satisfactory accuracy. Subject to further studies and extensive validation, our approach could inform a decision-support tool for optimizing vasopressor dosing on a per-patient basis.

PLoS Computational BiologyVol. 21(9)
Medical University of Lublin (PL), Institute of Biocybernetics and Biomedical Engineering (PL), Polish Academy of Sciences (PL)
Openalex Percentile: Top 63%
Cardiac Arrest and Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.