Thermal Behaviour of Piggyback-Laid District Heating and District Cooling Pipes

Abstract District heating (DH) and district cooling (DC) networks are key to sustainable urban energy systems. This study investigates thermal interactions between DH and DC pipelines installed in a piggyback configuration within a shared trench using a combination of in-situ temperature measurements and transient heat transfer simulations. A 175-meter section of Munich’s DH and DC network was analysed through experimental temperature measurements and a finite element method (FEM)-based thermal model in MATLAB. Results show that DH operation increases trench soil temperatures, leading to continuous heat gains in the DC flow pipe. Although the impact within the investigated area is limited due to the short piggyback-laid section, large-scale implementations will experience greater thermal interference. A simulated scenario without DH in operation confirmed that the pipe placement aligns ground temperatures with DC flow temperatures, avoiding heat gains. The validated model serves as a reliable tool for assessing heat losses and gains, contributing to future DH and DC network designs in urban infrastructure planning.

Authors

Institutions

Publication Details

Journal
Environmental and Climate Technologies
Published
2025-01-01
DOI
https://doi.org/10.2478/rtuect-2025-0034
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Behaviour of Piggyback-Laid District Heating and District Cooling Pipes

Ingo Weidlich, Aaron Wieland, Stefan Dollhopf
Environmental and Climate Technologies
Building Energy and Comfort Optimization
article

Thermal Behaviour of Piggyback-Laid District Heating and District Cooling Pipes

Ingo Weidlich, Aaron Wieland, Stefan Dollhopf
article en

Abstract

Abstract District heating (DH) and district cooling (DC) networks are key to sustainable urban energy systems. This study investigates thermal interactions between DH and DC pipelines installed in a piggyback configuration within a shared trench using a combination of in-situ temperature measurements and transient heat transfer simulations. A 175-meter section of Munich’s DH and DC network was analysed through experimental temperature measurements and a finite element method (FEM)-based thermal model in MATLAB. Results show that DH operation increases trench soil temperatures, leading to continuous heat gains in the DC flow pipe. Although the impact within the investigated area is limited due to the short piggyback-laid section, large-scale implementations will experience greater thermal interference. A simulated scenario without DH in operation confirmed that the pipe placement aligns ground temperatures with DC flow temperatures, avoiding heat gains. The validated model serves as a reliable tool for assessing heat losses and gains, contributing to future DH and DC network designs in urban infrastructure planning.

Environmental and Climate TechnologiesVol. 29(1)
HafenCity University Hamburg (DE)
Openalex Percentile: Top 73%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Thermal Behaviour of Piggyback-Laid District Heating and District Cooling Pipes — Ingo Weidlich, Aaron Wieland, et al. · Environmental and Climate Technologies (2025) | TGRS Research Map | TGRS