Optical Sensor for Scanning Angle of Micromirror with Improved 2D Calibration Method

The optical angle sensor demonstrates considerable potential to supersede the piezoresistive sensor as the preferred angle detection mechanism for micromirrors, primarily due to its reduced vulnerability to temperature fluctuations. However, this sensor is susceptible to interference from rotations about non-detectable axes and exhibits inadequate linearity. To mitigate these challenges, this paper introduces a sub-region calibration method. A mapping surface was created to link the output signal offsets of two axes with their input angles, allowing the effects of non-measured axes to be treated as variables. To simplify the mathematical model of this mapping surface, it was divided into an n-by-n grid of small areas. Each area uses bilinear interpolation to calculate the corresponding angle from the output values. To quickly locate which grid area a sensor output belongs to, the entire mapping surface was scaled to a range from 0 to n. Sensor outputs are then assigned to specific grid areas using the floor function. For validation, an optical sensor and a 2D rotating stage were built for calibration tests. Experimental results show that this calibration method keeps measurement errors below 0.01° within a ±8° operating range of the sensor.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-09-13
DOI
https://doi.org/10.3390/mi16091046
Citations
1
Primary Topic
Astronomical Observations and Instrumentation
Type
article
Field-Weighted Citation Impact
1.33

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical Sensor for Scanning Angle of Micromirror with Improved 2D Calibration Method

Jiahao Wu, Longqi Ran, Jiangbo He, Wu Zhou et al.
1 citations
Micromachines
Astronomical Observations and Instrumentation
1.33
article

Optical Sensor for Scanning Angle of Micromirror with Improved 2D Calibration Method

Jiahao Wu, Longqi Ran, Jiangbo He, Wu Zhou, Zhewang Ma, Ting Li
article en
1 citations

Abstract

The optical angle sensor demonstrates considerable potential to supersede the piezoresistive sensor as the preferred angle detection mechanism for micromirrors, primarily due to its reduced vulnerability to temperature fluctuations. However, this sensor is susceptible to interference from rotations about non-detectable axes and exhibits inadequate linearity. To mitigate these challenges, this paper introduces a sub-region calibration method. A mapping surface was created to link the output signal offsets of two axes with their input angles, allowing the effects of non-measured axes to be treated as variables. To simplify the mathematical model of this mapping surface, it was divided into an n-by-n grid of small areas. Each area uses bilinear interpolation to calculate the corresponding angle from the output values. To quickly locate which grid area a sensor output belongs to, the entire mapping surface was scaled to a range from 0 to n. Sensor outputs are then assigned to specific grid areas using the floor function. For validation, an optical sensor and a 2D rotating stage were built for calibration tests. Experimental results show that this calibration method keeps measurement errors below 0.01° within a ±8° operating range of the sensor.

MicromachinesVol. 16(9)
Xihua University (CN), University of Electronic Science and Technology of China (CN), Huawei Technologies (China) (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 18%
Astronomical Observations and Instrumentation
1.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optical Sensor for Scanning Angle of Micromirror with Improved 2D Calibration Method — Jiahao Wu, Longqi Ran, et al. · Micromachines (2025) | TGRS Research Map | TGRS