Advancing Wastewater Surveillance: Development of High-Throughput Green Robotic SPE-UPLC-MS/MS Workflow for Monitoring of 27 Steroids and Hormones

Conventional methods for testing steroids and hormones (SHs) in environmental samples are exhaustive, complex, and score poorly in sustainability matrices. Therefore, this study evaluates the automated sample preparation approach using the modular Biomek i7 Workstation for the analysis of 27 SHs in wastewater. Method development involved optimizing Ultra Performance Liquid Chromatography–Tandem Mass Spectrometry (UPLC-MS/MS) parameters, preparing wastewater matrix blank, and assessing extraction efficiency using three solid phase extraction (SPE) cartridges. Extraction efficiency trials showed suitability in the order of Hydrophilic–Lipophilic Balance (HLB) > Mixed-Mode Cation Exchange (MCX) > Mixed-Mode Anion Exchange (MAX). The method demonstrated specificity for all targeted SHs, with Cholesterol showing a maximum interfering peak of 17.71% of the quantification limit (LOQ). The method met matrix effect tolerance of ±20% for 26 SHs, while Epi Coprostanol (34.92%) showed signal enhancement >20%. The 8-point calibration curve plotted using automated extraction demonstrated acceptable linearity across the tested range. Spiked studies at low (LQC), middle (MQC), and higher (HQC) quality control (QC) levels (n = 6, repeated on three separate occasions) demonstrated % RSD values within 20% and recoveries ranging from 71.54% to 115.00%. The method met validation criteria, showing reliability in Intra-Laboratory Comparison (ILC) and Blind Testing (BT). The method outperformed the conventional approach in greenness assessment (Complex Modified Green Analytical Procedure Index) and practicality evaluation (Blue Applicability Grade Index), offering an effective and sustainable protocol for environmental testing laboratories.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-09-12
DOI
https://doi.org/10.3390/app151810012
Citations
2
Primary Topic
Pharmaceutical and Antibiotic Environmental Impacts
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancing Wastewater Surveillance: Development of High-Throughput Green Robotic SPE-UPLC-MS/MS Workflow for Monitoring of 27 Steroids and Hormones

Raghu Tadala, Dnyaneshwar Shinde, Wael Elamin, Grzegorz Brudecki et al.
2 citations
Applied Sciences
Pharmaceutical and Antibiotic Environmental Impacts
1.01
article

Advancing Wastewater Surveillance: Development of High-Throughput Green Robotic SPE-UPLC-MS/MS Workflow for Monitoring of 27 Steroids and Hormones

Raghu Tadala, Dnyaneshwar Shinde, Wael Elamin, Grzegorz Brudecki, Samara Bin Salem, Bhaskar Karubothula, Chaitanya Devireddy, Rizwan Shukoor, Ghenwa Hafez
article en
2 citations

Abstract

Conventional methods for testing steroids and hormones (SHs) in environmental samples are exhaustive, complex, and score poorly in sustainability matrices. Therefore, this study evaluates the automated sample preparation approach using the modular Biomek i7 Workstation for the analysis of 27 SHs in wastewater. Method development involved optimizing Ultra Performance Liquid Chromatography–Tandem Mass Spectrometry (UPLC-MS/MS) parameters, preparing wastewater matrix blank, and assessing extraction efficiency using three solid phase extraction (SPE) cartridges. Extraction efficiency trials showed suitability in the order of Hydrophilic–Lipophilic Balance (HLB) > Mixed-Mode Cation Exchange (MCX) > Mixed-Mode Anion Exchange (MAX). The method demonstrated specificity for all targeted SHs, with Cholesterol showing a maximum interfering peak of 17.71% of the quantification limit (LOQ). The method met matrix effect tolerance of ±20% for 26 SHs, while Epi Coprostanol (34.92%) showed signal enhancement >20%. The 8-point calibration curve plotted using automated extraction demonstrated acceptable linearity across the tested range. Spiked studies at low (LQC), middle (MQC), and higher (HQC) quality control (QC) levels (n = 6, repeated on three separate occasions) demonstrated % RSD values within 20% and recoveries ranging from 71.54% to 115.00%. The method met validation criteria, showing reliability in Intra-Laboratory Comparison (ILC) and Blind Testing (BT). The method outperformed the conventional approach in greenness assessment (Complex Modified Green Analytical Procedure Index) and practicality evaluation (Blue Applicability Grade Index), offering an effective and sustainable protocol for environmental testing laboratories.

Applied SciencesVol. 15(18)
Abu Dhabi Department of Education and Knowledge (AE)
Openalex Percentile: Top 23%
Pharmaceutical and Antibiotic Environmental Impacts
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.