Multi-parameter assessment of osteoporosis based on x-ray induced acoustic computed tomography

X-ray induced acoustic computed tomography (XACT) reconstructed the internal x-ray absorption distribution of bone tissue through the ultrasound generation by the thermoelastic effect. In this paper, we proposed a method for multi-parameter assessment of osteoporosis using XACT technology. The relationship between the x-ray induced acoustic (XA) signal and the viscoelasticity of bone tissue was investigated theoretically. Through XACT simulation experiments, multi-parameter such as bone density, content, elasticity, and viscosity can be characterized qualitatively by extracting XA signal intensity, spatial proportion, and XA displacement time from the reconstructed XACT images. Experimental results showed that this method can provide comprehensive multi-parameter information on skeletal tissue, demonstrating potential application value in the skeletal assessment of osteoporosis.

Authors

Institutions

Publication Details

Journal
Applied Physics Letters
Published
2025-09-08
DOI
https://doi.org/10.1063/5.0287184
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-parameter assessment of osteoporosis based on x-ray induced acoustic computed tomography

Jiyuan Fan, Zhao Li, Yue Zhao, Chenglong Du
Applied Physics Letters
Photoacoustic and Ultrasonic Imaging
article

Multi-parameter assessment of osteoporosis based on x-ray induced acoustic computed tomography

Jiyuan Fan, Zhao Li, Yue Zhao, Chenglong Du
article en

Abstract

X-ray induced acoustic computed tomography (XACT) reconstructed the internal x-ray absorption distribution of bone tissue through the ultrasound generation by the thermoelastic effect. In this paper, we proposed a method for multi-parameter assessment of osteoporosis using XACT technology. The relationship between the x-ray induced acoustic (XA) signal and the viscoelasticity of bone tissue was investigated theoretically. Through XACT simulation experiments, multi-parameter such as bone density, content, elasticity, and viscosity can be characterized qualitatively by extracting XA signal intensity, spatial proportion, and XA displacement time from the reconstructed XACT images. Experimental results showed that this method can provide comprehensive multi-parameter information on skeletal tissue, demonstrating potential application value in the skeletal assessment of osteoporosis.

Applied Physics LettersVol. 127(10)
Shandong University of Technology (CN)
Openalex Percentile: Top 77%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Multi-parameter assessment of osteoporosis based on x-ray induced acoustic computed tomography — Jiyuan Fan, Zhao Li, et al. · Applied Physics Letters (2025) | TGRS Research Map | TGRS