Relative SNR Measurement with Supine versus Prone Positioning in Breast MRI

Motivation: The current imaging setup for breast MRI is for the patient to be in the prone position. Recent coil advancements have enabled fast supine breast imaging, but this is not widely adapted. Goal(s): Analyze potential SNR differences between Breast MRI in prone and supine positions. Approach: We analyzed relative SNR differences between prone and supine by computing SNR maps for each position, using a body coil SNR map as a reference. Results: The in vivo comparison showed a difference in potential SNR between imaging in the prone vs. supine positions, specifically for patients with smaller breast sizes. Impact: Breast MRI has emerged as a key component to breast cancer imaging. However, the prone setup is uncomfortable for many patients. Being able to scan in supine with potential SNR benefits would allow for a robust supine breast MRI protocol.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2124
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Relative SNR Measurement with Supine versus Prone Positioning in Breast MRI

Jeremiah Hess, Catherine J. Moran, Bruce L. Daniel, Jana Vincent et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Relative SNR Measurement with Supine versus Prone Positioning in Breast MRI

Jeremiah Hess, Catherine J. Moran, Bruce L. Daniel, Jana Vincent, Preya Shah, Fraser Robb, Brian Hargreaves
article en

Abstract

Motivation: The current imaging setup for breast MRI is for the patient to be in the prone position. Recent coil advancements have enabled fast supine breast imaging, but this is not widely adapted. Goal(s): Analyze potential SNR differences between Breast MRI in prone and supine positions. Approach: We analyzed relative SNR differences between prone and supine by computing SNR maps for each position, using a body coil SNR map as a reference. Results: The in vivo comparison showed a difference in potential SNR between imaging in the prone vs. supine positions, specifically for patients with smaller breast sizes. Impact: Breast MRI has emerged as a key component to breast cancer imaging. However, the prone setup is uncomfortable for many patients. Being able to scan in supine with potential SNR benefits would allow for a robust supine breast MRI protocol.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 66%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.