Proposed Reliability Prediction Model for Power Transformer Based on 2-FAL

Accurately estimating the remaining useful life (RUL) of power transformers is critical for maintaining the reliability and efficiency of electrical power systems. This study proposes a novel empirical model to estimate the degree of polymerization (DP) - a critical measure of insulation deterioration in transformers - by analyzing 2-furfuraldehyde (2-FAL) concentration. Developed using a dataset of 125 samples from published literature, the model employs logarithmic regression to capture the exponential relationship between 2-FAL accumulation and insulation deterioration. Validation through comparison with Chengdong's model and other existing approaches, with performance metrics including and R-square of 0.9917, mean absolute error (MAE) of 58.08, and root mean square error (RMSE) of 86.59. The model's predictions for 2-FAL concentration in ranges of 0–5 ppm and 0–40 ppm closely align with the measured DP values. More specifically, it reflects a rapid initial decline followed by gradual stabilization at higher concentrations. The high-precision DP estimation enhances RUL prediction accuracy, offering a robust foundation for data-driven maintenance strategies for power transformers.

Authors

Institutions

Publication Details

Published
2025-07-25
DOI
https://doi.org/10.1109/atigb66719.2025.11142212
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proposed Reliability Prediction Model for Power Transformer Based on 2-FAL

Duc-Hanh Dinh, Duong D. Le, Kim Anh Nguyen, Huy Vu Tran
Power Transformer Diagnostics and Insulation
article

Proposed Reliability Prediction Model for Power Transformer Based on 2-FAL

Duc-Hanh Dinh, Duong D. Le, Kim Anh Nguyen, Huy Vu Tran
article en

Abstract

Accurately estimating the remaining useful life (RUL) of power transformers is critical for maintaining the reliability and efficiency of electrical power systems. This study proposes a novel empirical model to estimate the degree of polymerization (DP) - a critical measure of insulation deterioration in transformers - by analyzing 2-furfuraldehyde (2-FAL) concentration. Developed using a dataset of 125 samples from published literature, the model employs logarithmic regression to capture the exponential relationship between 2-FAL accumulation and insulation deterioration. Validation through comparison with Chengdong's model and other existing approaches, with performance metrics including and R-square of 0.9917, mean absolute error (MAE) of 58.08, and root mean square error (RMSE) of 86.59. The model's predictions for 2-FAL concentration in ranges of 0–5 ppm and 0–40 ppm closely align with the measured DP values. More specifically, it reflects a rapid initial decline followed by gradual stabilization at higher concentrations. The high-precision DP estimation enhances RUL prediction accuracy, offering a robust foundation for data-driven maintenance strategies for power transformers.

University of Da Nang (VN)
Openalex Percentile: Top 76%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Proposed Reliability Prediction Model for Power Transformer Based on 2-FAL — Duc-Hanh Dinh, Duong D. Le, et al. · (2025) | TGRS Research Map | TGRS