Robust Control Based on Unknown Input Disturbance Observer for Fully Actuated Systems

In this paper, an unknown input disturbance observer is first designed for the single-order fully actuated systems with multiple disturbances. Due to the decoupling design, the observations of external disturbances are not affected by the discontinuous signals in the system. Furthermore, the sufficient and necessary condition for the existence of the observer is also given. Then a robust control scheme is proposed on the basis of full-actuation property. The controller not only utilizes the estimated values to compensate for the external disturbances, but also employs robust method to suppress the effect of discontinuous signals in the system, making the states of the closed-loop system ultimate boundness. An interconnected inverted pendulum simulation is provided to verify the effectiveness of the unknown input disturbance observer and the robust controller.

Authors

Institutions

Publication Details

Published
2025-07-04
DOI
https://doi.org/10.1109/fasta65681.2025.11138766
Primary Topic
Adaptive Control of Nonlinear Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust Control Based on Unknown Input Disturbance Observer for Fully Actuated Systems

Guang‐Ren Duan, Hong Jiang
Adaptive Control of Nonlinear Systems
article

Robust Control Based on Unknown Input Disturbance Observer for Fully Actuated Systems

Guang‐Ren Duan, Hong Jiang
article en

Abstract

In this paper, an unknown input disturbance observer is first designed for the single-order fully actuated systems with multiple disturbances. Due to the decoupling design, the observations of external disturbances are not affected by the discontinuous signals in the system. Furthermore, the sufficient and necessary condition for the existence of the observer is also given. Then a robust control scheme is proposed on the basis of full-actuation property. The controller not only utilizes the estimated values to compensate for the external disturbances, but also employs robust method to suppress the effect of discontinuous signals in the system, making the states of the closed-loop system ultimate boundness. An interconnected inverted pendulum simulation is provided to verify the effectiveness of the unknown input disturbance observer and the robust controller.

Harbin Institute of Technology (CN)
Openalex Percentile: Top 70%
Adaptive Control of Nonlinear Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.