The integration of sensing and communication functions in one platform has become a pivotal use case in future communication systems. This research investigated the optimal integrated sensing and communication (ISAC) waveforms for the purpose of vital signs detection. In order to incorporate both functions in the system and make it favorable for sensing the micro-doppler effect associated with vital signs, orthogonal frequency division multiplexing (OFDM) and phase-coded frequency modulated continuous wave (PC-FMCW) signals were adopted and compared, and the performances were evaluated against the system based on the classic frequency modulated continuous wave (FMCW). Several phase coded FMCW signals have been investigated and the simulated results indicated that the Frank-coded PC-FMCW waveform exhibited an optimal performance for vital signs detection in a line-of-sight setting. The work is beneficial for search and rescue applications where high-performance sensing such as vital signs detection and limited communication capability is required.

Authors

Institutions

Publication Details

Published
2025-08-10
DOI
https://doi.org/10.1109/icccworkshops67136.2025.11148186
Primary Topic
Radar Systems and Signal Processing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Waveform Design for Vital Signs Detection in Integrated Sensing and Communication System

Yongwei Zhang, Delong Xing, Murat Temiz, Chi Zhang
Radar Systems and Signal Processing
article

Waveform Design for Vital Signs Detection in Integrated Sensing and Communication System

Yongwei Zhang, Delong Xing, Murat Temiz, Chi Zhang
article en

Abstract

The integration of sensing and communication functions in one platform has become a pivotal use case in future communication systems. This research investigated the optimal integrated sensing and communication (ISAC) waveforms for the purpose of vital signs detection. In order to incorporate both functions in the system and make it favorable for sensing the micro-doppler effect associated with vital signs, orthogonal frequency division multiplexing (OFDM) and phase-coded frequency modulated continuous wave (PC-FMCW) signals were adopted and compared, and the performances were evaluated against the system based on the classic frequency modulated continuous wave (FMCW). Several phase coded FMCW signals have been investigated and the simulated results indicated that the Frank-coded PC-FMCW waveform exhibited an optimal performance for vital signs detection in a line-of-sight setting. The work is beneficial for search and rescue applications where high-performance sensing such as vital signs detection and limited communication capability is required.

Nantong University (CN), University College London (GB)
Openalex Percentile: Top 67%
Radar Systems and Signal Processing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.