Ultra-High Frequency Localization Method for Transformer Partial Discharge based on TDOA and WLS-FA

Partial discharge is one of the main features of internal insulation defects in transformers and other high-voltage electrical equipment, and ultra-high frequency detection methods have been widely used in PD monitoring by virtue of their high sensitivity and strong anti-interference capability. To achieve 3D accurate localization of transformer partial discharge sources, this paper proposes an improved localization strategy based on the arrival time difference model and the weighted least squares-firefly algorithm. First, the WLS method is used to linearize the measured TDOA data to obtain the initial solution, and then the Firefly algorithm is used to optimize the search in the region near the initial solution to correct the possible deviation of WLS in noisy environments or when the initial value is poor. Simulation example is provided to verify the significant improvement in localization accuracy and stability of the proposed WLS-FA localization method. This brings theoretical significance and practical application for transformer partial discharge monitoring and equipment condition maintenance.

Authors

Institutions

Publication Details

Published
2025-07-04
DOI
https://doi.org/10.1109/fasta65681.2025.11138886
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra-High Frequency Localization Method for Transformer Partial Discharge based on TDOA and WLS-FA

Yunlong Du, Xingkai Yu, Jiahui Dai, X. F. Duan
High voltage insulation and dielectric phenomena
article

Ultra-High Frequency Localization Method for Transformer Partial Discharge based on TDOA and WLS-FA

Yunlong Du, Xingkai Yu, Jiahui Dai, X. F. Duan
article en

Abstract

Partial discharge is one of the main features of internal insulation defects in transformers and other high-voltage electrical equipment, and ultra-high frequency detection methods have been widely used in PD monitoring by virtue of their high sensitivity and strong anti-interference capability. To achieve 3D accurate localization of transformer partial discharge sources, this paper proposes an improved localization strategy based on the arrival time difference model and the weighted least squares-firefly algorithm. First, the WLS method is used to linearize the measured TDOA data to obtain the initial solution, and then the Firefly algorithm is used to optimize the search in the region near the initial solution to correct the possible deviation of WLS in noisy environments or when the initial value is poor. Simulation example is provided to verify the significant improvement in localization accuracy and stability of the proposed WLS-FA localization method. This brings theoretical significance and practical application for transformer partial discharge monitoring and equipment condition maintenance.

North China Electric Power University (CN)
Openalex Percentile: Top 81%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.