Automated Grid Detection in Hemocytometer Images Using Canny and Hough Line Transform for Cell Quantification

Accurate cell quantification using a hemocytometer requires identifying a defined Area of Interest (AOI) rather than analyzing the entire image. Manual selection of this region is time-consuming and error-prone, particularly when processing large datasets. To address this, we propose a fully automated method for AOI detection in hemocytometer images (microscope images of hemocytometer grids), aimed at improving lung cancer cell quantification. The original image is first converted to grayscale, then the Sobel algorithm is applied to generate two variants highlighting edge features in the horizontal and vertical directions, respectively. These variants are subsequently processed using the Canny edge detection algorithm and the Hough line transform to extract grid-like structures. However, this process often introduces noise, such as overlapping or redundant lines and irrelevant detections. To overcome this, we propose a filtering and identification algorithm to refine the results and accurately determine the signature lines that define the hemocytometer AOI. Experimental results confirm that the proposed method offers both high accuracy and processing speed compared to manual approaches. The fully automated system, which integrates AOI detection with a YOLOv8m-based cell detection model, achieved a precision of 0.91, recall of 0.87, and mAP@50 of 0.93. The overall F1-score reached approximately 0.891, reflecting a strong balance between sensitivity and specificity. In high-density cell samples, the average counting error compared to manual methods was below 11.3%, while in low-density samples, it was under 2.6%. These findings demonstrate the method's effectiveness and potential for reliable, standardized cell quantification in biomedical applications.

Authors

Institutions

Publication Details

Published
2025-07-25
DOI
https://doi.org/10.1109/atigb66719.2025.11142152
Primary Topic
Digital Imaging for Blood Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated Grid Detection in Hemocytometer Images Using Canny and Hough Line Transform for Cell Quantification

Minh Tri Ho, Minh Le Quang Nhat, Linh Huynh Thi Thuy, Dat Tran et al.
Digital Imaging for Blood Diseases
article

Automated Grid Detection in Hemocytometer Images Using Canny and Hough Line Transform for Cell Quantification

Minh Tri Ho, Minh Le Quang Nhat, Linh Huynh Thi Thuy, Dat Tran, Le-Minh Nguyen, Chun‐Ping Jen, Minh Le Thien
article en

Abstract

Accurate cell quantification using a hemocytometer requires identifying a defined Area of Interest (AOI) rather than analyzing the entire image. Manual selection of this region is time-consuming and error-prone, particularly when processing large datasets. To address this, we propose a fully automated method for AOI detection in hemocytometer images (microscope images of hemocytometer grids), aimed at improving lung cancer cell quantification. The original image is first converted to grayscale, then the Sobel algorithm is applied to generate two variants highlighting edge features in the horizontal and vertical directions, respectively. These variants are subsequently processed using the Canny edge detection algorithm and the Hough line transform to extract grid-like structures. However, this process often introduces noise, such as overlapping or redundant lines and irrelevant detections. To overcome this, we propose a filtering and identification algorithm to refine the results and accurately determine the signature lines that define the hemocytometer AOI. Experimental results confirm that the proposed method offers both high accuracy and processing speed compared to manual approaches. The fully automated system, which integrates AOI detection with a YOLOv8m-based cell detection model, achieved a precision of 0.91, recall of 0.87, and mAP@50 of 0.93. The overall F1-score reached approximately 0.891, reflecting a strong balance between sensitivity and specificity. In high-density cell samples, the average counting error compared to manual methods was below 11.3%, while in low-density samples, it was under 2.6%. These findings demonstrate the method's effectiveness and potential for reliable, standardized cell quantification in biomedical applications.

National Chung Cheng University (TW), Hue University (VN), Le Hong Phong High School for the Gifted (VN), Services déconcentrés d'appui à la recherche Val de Loire (FR), Institut National des Sciences Appliquées Centre Val de Loire (FR)
Openalex Percentile: Top 76%
Digital Imaging for Blood Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.