[Development of Synchronous Arbitrary Gate-PW Doppler for Ultrasound Microvascular Imaging and Preliminary Validation].

Ultra micro angiography (UMA) can effectively improve the sensitivity and spatial resolution of blood flow imaging. To further meet the clinical requirements of quantitative measurements for microvascular imaging, this article demonstrated technical features and performance verification results of the microflow quantitative analysis function, which was developed based on the UMA function. This article provided preliminary validation of the measurement of Synchronous Arbitrary Gate-PW (SAG-PW) using a Doppler flow phantom and a moving string phantom. The Doppler flow phantom results demonstrated that the SAG-PW measurement values were close to the traditional PW results, and the average error of multiple sets of measurement results under different conditions was 3.9%. The results of SAG-PW and PW were strongly linearly correlated, with the slope and correlation coefficient approaching 1. The results of the moving string phantom demonstrated that the relative errors of TAMean and SAG-PW with different phantom set values were within 10%.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-07-30
DOI
https://doi.org/10.12455/j.issn.1671-7104.240675
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Development of Synchronous Arbitrary Gate-PW Doppler for Ultrasound Microvascular Imaging and Preliminary Validation].

Lanxi Xiang, Yigang Du, Chao Li, Zhizhong Zheng et al.
PubMed
Ultrasound and Hyperthermia Applications
article

[Development of Synchronous Arbitrary Gate-PW Doppler for Ultrasound Microvascular Imaging and Preliminary Validation].

Lanxi Xiang, Yigang Du, Chao Li, Zhizhong Zheng, Shuangshuang Li
article en

Abstract

Ultra micro angiography (UMA) can effectively improve the sensitivity and spatial resolution of blood flow imaging. To further meet the clinical requirements of quantitative measurements for microvascular imaging, this article demonstrated technical features and performance verification results of the microflow quantitative analysis function, which was developed based on the UMA function. This article provided preliminary validation of the measurement of Synchronous Arbitrary Gate-PW (SAG-PW) using a Doppler flow phantom and a moving string phantom. The Doppler flow phantom results demonstrated that the SAG-PW measurement values were close to the traditional PW results, and the average error of multiple sets of measurement results under different conditions was 3.9%. The results of SAG-PW and PW were strongly linearly correlated, with the slope and correlation coefficient approaching 1. The results of the moving string phantom demonstrated that the relative errors of TAMean and SAG-PW with different phantom set values were within 10%.

PubMedVol. 49(4)
Mindray (China) (CN)
Openalex Percentile: Top 77%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

[Development of Synchronous Arbitrary Gate-PW Doppler for Ultrasound Microvascular Imaging and Preliminary Validation]. — Lanxi Xiang, Yigang Du, et al. · PubMed (2025) | TGRS Research Map | TGRS