Machine learning-powered plasmonic pattern recognition: etch-suppressed gold nanorods for multiplex urinary analysis of catecholamine neurotransmitters

Simultaneous monitoring of catecholamine neurotransmitters (CNTs)-including epinephrine (Epi), norepinephrine (NE), levodopa (L-DOPA), and dopamine (DA)-is essential for the accurate diagnosis and effective management of various neurological disorders. However, most existing sensing platforms face challenges such as limited multiplexing capabilities and potential cytotoxicity of the sensing components. In this work, we introduce a sensitive, non-toxic, and non-invasive single-component multicolorimetric probe capable of detecting and distinguishing low concentrations of Epi, NE, L-DOPA, and DA, along with their binary, ternary, and quaternary mixtures. The sensing mechanism relies on the controlled inhibition of gold nanorod (AuNR) etching in the presence of varying concentrations of <i>N</i>-bromosuccinimide (NBS), a mild oxidizing agent, under ambient conditions. To enable robust analyte identification and quantification, the spectral responses were processed using machine learning algorithms-specifically, linear discriminant analysis (LDA) for classification and partial least squares regression (PLSR) for concentration prediction. Under the optimized conditions, the assay demonstrated excellent linearity across a broad concentration range for each analyte, Epi (1.8-20 μmol L<sup>-1</sup>), NE (1.4-25 μmol L<sup>-1</sup>), L-DOPA (1.5-25 μmol L<sup>-1</sup>), and DA (2.8-50 μmol L<sup>-1</sup>), with corresponding detection limits of 0.62, 0.47, 0.49, and 0.92 μmol L<sup>-1</sup>. The practical utility of the platform was validated through successful application to human urine samples, confirming its potential as a powerful tool for point-of-care diagnostics and clinical neurochemical analysis.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00976f
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine learning-powered plasmonic pattern recognition: etch-suppressed gold nanorods for multiplex urinary analysis of catecholamine neurotransmitters

M. Reza Hormozi‐Nezhad, Afsaneh Orouji, Mahsa Daneshmandi
Analytical Methods
Advanced biosensing and bioanalysis techniques
article

Machine learning-powered plasmonic pattern recognition: etch-suppressed gold nanorods for multiplex urinary analysis of catecholamine neurotransmitters

M. Reza Hormozi‐Nezhad, Afsaneh Orouji, Mahsa Daneshmandi
article en

Abstract

Simultaneous monitoring of catecholamine neurotransmitters (CNTs)-including epinephrine (Epi), norepinephrine (NE), levodopa (L-DOPA), and dopamine (DA)-is essential for the accurate diagnosis and effective management of various neurological disorders. However, most existing sensing platforms face challenges such as limited multiplexing capabilities and potential cytotoxicity of the sensing components. In this work, we introduce a sensitive, non-toxic, and non-invasive single-component multicolorimetric probe capable of detecting and distinguishing low concentrations of Epi, NE, L-DOPA, and DA, along with their binary, ternary, and quaternary mixtures. The sensing mechanism relies on the controlled inhibition of gold nanorod (AuNR) etching in the presence of varying concentrations of <i>N</i>-bromosuccinimide (NBS), a mild oxidizing agent, under ambient conditions. To enable robust analyte identification and quantification, the spectral responses were processed using machine learning algorithms-specifically, linear discriminant analysis (LDA) for classification and partial least squares regression (PLSR) for concentration prediction. Under the optimized conditions, the assay demonstrated excellent linearity across a broad concentration range for each analyte, Epi (1.8-20 μmol L<sup>-1</sup>), NE (1.4-25 μmol L<sup>-1</sup>), L-DOPA (1.5-25 μmol L<sup>-1</sup>), and DA (2.8-50 μmol L<sup>-1</sup>), with corresponding detection limits of 0.62, 0.47, 0.49, and 0.92 μmol L<sup>-1</sup>. The practical utility of the platform was validated through successful application to human urine samples, confirming its potential as a powerful tool for point-of-care diagnostics and clinical neurochemical analysis.

Analytical MethodsVol. 17(37)
Sharif University of Technology (IR)
Openalex Percentile: Top 78%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Machine learning-powered plasmonic pattern recognition: etch-suppressed gold nanorods for multiplex urinary analysis of catecholamine neurotransmitters — M. Reza Hormozi‐Nezhad, Afsaneh Orouji, et al. · Analytical Methods (2025) | TGRS Research Map | TGRS