The Performance of Current Differential Protection in a Distribution Network Containing Grid-Forming Distributed Generators

This paper addresses the misoperation and refusal issues of current differential protection caused by grid-forming distributed generation integration into active distribution networks. Through establishing a virtual synchronous machine control model for grid-forming distributed generation and conducting fault sequence network analysis, the mechanism of output current phase shift during low-voltage ride-through (LVRT) affecting differential protection criteria is revealed. The study demonstrates that during external faults, grid-forming distributed generation injects reverse short-circuit currents causing virtual increases in differential currents, significantly elevating traditional criteria misoperation rates. During internal faults, controlled current outputs reduce protection sensitivity. The theoretical analysis is ultimately validated through simulation verification.

Authors

Institutions

Publication Details

Published
2025-07-25
DOI
https://doi.org/10.1109/aceee66257.2025.11148640
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Performance of Current Differential Protection in a Distribution Network Containing Grid-Forming Distributed Generators

Dong Wang, Ziqi Liu
Power Systems Fault Detection
article

The Performance of Current Differential Protection in a Distribution Network Containing Grid-Forming Distributed Generators

Dong Wang, Ziqi Liu
article en

Abstract

This paper addresses the misoperation and refusal issues of current differential protection caused by grid-forming distributed generation integration into active distribution networks. Through establishing a virtual synchronous machine control model for grid-forming distributed generation and conducting fault sequence network analysis, the mechanism of output current phase shift during low-voltage ride-through (LVRT) affecting differential protection criteria is revealed. The study demonstrates that during external faults, grid-forming distributed generation injects reverse short-circuit currents causing virtual increases in differential currents, significantly elevating traditional criteria misoperation rates. During internal faults, controlled current outputs reduce protection sensitivity. The theoretical analysis is ultimately validated through simulation verification.

Qingdao University of Science and Technology (CN)
Openalex Percentile: Top 70%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Performance of Current Differential Protection in a Distribution Network Containing Grid-Forming Distributed Generators — Dong Wang, Ziqi Liu · (2025) | TGRS Research Map | TGRS