Reconfigurable sensors with Shape-Shifting Robots

The integration of multiple sensors plays a crucial role in various applications such as autonomous navigation, object detection, and perception. Achieving accurate and meaningful results necessitates a robust calibration approach, particularly focusing on the intrinsic and extrinsic calibration of sensors, assuming their fixed positioning relative to each other. However, the emergence of reconfigurable robots capable of altering their morphology presents a unique challenge in sensor calibration. Unlike conventional setups where sensors remain stationary postcalibration, the dynamic nature of reconfigurable robots results in the constant change of sensor positions. This necessitates continuous adjustments in calibration to accommodate these positional variations, ensuring the system’s operational integrity and accuracy. Failure to address this can result in issues like the hallucination effect, impairing the robot’s operational efficacy. This article proposes an adaptive transformation approach to address this challenge effectively, enabling real-time tracking of changes in the relative pose of sensors. In this article, we validate the efficacy of the proposed scheme through simulation and real-life experiment results that showcase the reduction of sensor hallucination while ensuring the robustness of the robot’s perception capabilities. This article presents and discusses results demonstrating the effectiveness of the adaptive transformation approach in two distinct cases. Importantly, the proposed framework is designed to be generic, making it applicable to a wide range of multisensory calibration scenarios where each sensor is subject to changes in relative pose. Our proposed algorithm outperforms the state-of-the-art method by a factor of 31, achieving a root mean square error (RMSE) of just 2 ms.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-01-01
DOI
https://doi.org/10.1109/jsen.2025.3605064
Primary Topic
Modular Robots and Swarm Intelligence
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reconfigurable sensors with Shape-Shifting Robots

Ash Yaw Sang Wan, Mohan Rajesh Elara, Abdullah Aamir Hayat, Jinjie Huang et al.
IEEE Sensors Journal
Modular Robots and Swarm Intelligence
article

Reconfigurable sensors with Shape-Shifting Robots

Ash Yaw Sang Wan, Mohan Rajesh Elara, Abdullah Aamir Hayat, Jinjie Huang, Manimaran Maathavan
article en

Abstract

The integration of multiple sensors plays a crucial role in various applications such as autonomous navigation, object detection, and perception. Achieving accurate and meaningful results necessitates a robust calibration approach, particularly focusing on the intrinsic and extrinsic calibration of sensors, assuming their fixed positioning relative to each other. However, the emergence of reconfigurable robots capable of altering their morphology presents a unique challenge in sensor calibration. Unlike conventional setups where sensors remain stationary postcalibration, the dynamic nature of reconfigurable robots results in the constant change of sensor positions. This necessitates continuous adjustments in calibration to accommodate these positional variations, ensuring the system’s operational integrity and accuracy. Failure to address this can result in issues like the hallucination effect, impairing the robot’s operational efficacy. This article proposes an adaptive transformation approach to address this challenge effectively, enabling real-time tracking of changes in the relative pose of sensors. In this article, we validate the efficacy of the proposed scheme through simulation and real-life experiment results that showcase the reduction of sensor hallucination while ensuring the robustness of the robot’s perception capabilities. This article presents and discusses results demonstrating the effectiveness of the adaptive transformation approach in two distinct cases. Importantly, the proposed framework is designed to be generic, making it applicable to a wide range of multisensory calibration scenarios where each sensor is subject to changes in relative pose. Our proposed algorithm outperforms the state-of-the-art method by a factor of 31, achieving a root mean square error (RMSE) of just 2 ms.

IEEE Sensors Journal
Singapore University of Technology and Design (SG), United Arab Emirates University (AE)
Openalex Percentile: Top 75%
Modular Robots and Swarm Intelligence
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.