Intelligent Early Warning Method for Substations Based on Digital Twin

With the increasing demand for emergency response speed and early warning efficiency in substations, traditional safety early warning methods can no longer meet the requirements of modern power systems. Therefore, this paper proposes an intelligent early warning method for substations based on digital twin technology, which achieves dual early warning for substation faults. First, preliminary intelligent early warning judgments are made on parameters based on thresholds and trends. Then, by employing a combination weighting method to assign weights to each parameter and performing weighted fuzzy C-means clustering on the normalized data of each substation, multiple normal operating modes for each substation are obtained. Based on the identified normal operating modes, the operating state of the substation is comprehensively assessed according to the severity of the abnormality, thereby enabling comprehensive early warning. The results of the case study demonstrate that the proposed method can effectively identify substation faults.

Authors

Institutions

Publication Details

Published
2025-07-25
DOI
https://doi.org/10.1109/aceee66257.2025.11149022
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intelligent Early Warning Method for Substations Based on Digital Twin

Yan Liu, Wei Guo, Cui Wanzhou, Xin Xiaoyu et al.
Smart Grid and Power Systems
article

Intelligent Early Warning Method for Substations Based on Digital Twin

Yan Liu, Wei Guo, Cui Wanzhou, Xin Xiaoyu, Wu Qiu-Wei, Zhao Zigen
article en

Abstract

With the increasing demand for emergency response speed and early warning efficiency in substations, traditional safety early warning methods can no longer meet the requirements of modern power systems. Therefore, this paper proposes an intelligent early warning method for substations based on digital twin technology, which achieves dual early warning for substation faults. First, preliminary intelligent early warning judgments are made on parameters based on thresholds and trends. Then, by employing a combination weighting method to assign weights to each parameter and performing weighted fuzzy C-means clustering on the normalized data of each substation, multiple normal operating modes for each substation are obtained. Based on the identified normal operating modes, the operating state of the substation is comprehensively assessed according to the severity of the abnormality, thereby enabling comprehensive early warning. The results of the case study demonstrate that the proposed method can effectively identify substation faults.

Tianjin University (CN), Shenzhen Stock Exchange (CN), Tsinghua–Berkeley Shenzhen Institute (CN), Peng Cheng Laboratory (CN)
Openalex Percentile: Top 76%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Intelligent Early Warning Method for Substations Based on Digital Twin — Yan Liu, Wei Guo, et al. · (2025) | TGRS Research Map | TGRS