Analysis of DR’s AC/DC-Side Impedance Modeling Based on Harmonic Linearization

The diode rectifier (DR), characterized by its small size, light weight, and low cost, has significant development prospects in lightweight offshore converters. However, the AC/DC-side interaction between the DR and its cascaded system can easily cause oscillation. Impedance analysis is fundamental for studying the stability of cascaded systems. Based on harmonic linearization, this paper derives a frequency-domain small signal model that includes the DR’s improved switching function and commutation process. Considering the cascaded system impedances and commutation disturbance, the frequency coupling mechanism in the DR’s AC sequence impedance is analyzed. Subsequently, a detailed AC/DC-side impedance model of the DR is established, using an impedance matrix form to uniformly model both AC and DC sides, which can connect with the impedance matrix of multi-harmonic response systems. The results indicate that commutation disturbance and frequency coupling significantly affect the DR’s impedance characteristics in the mid and low frequency bands. Finally, the correctness of the DR’s AC/DC-side impedance model is verified through Matlab/Simulink simulation.

Authors

Institutions

Publication Details

Published
2025-07-25
DOI
https://doi.org/10.1109/aceee66257.2025.11149254
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of DR’s AC/DC-Side Impedance Modeling Based on Harmonic Linearization

H. J. Wang, Zhijie Liu, Honglin Chen, Feng Li et al.
High-Voltage Power Transmission Systems
article

Analysis of DR’s AC/DC-Side Impedance Modeling Based on Harmonic Linearization

H. J. Wang, Zhijie Liu, Honglin Chen, Feng Li, Minjia Zheng, Hao Yu, Jinxin Dou
article en

Abstract

The diode rectifier (DR), characterized by its small size, light weight, and low cost, has significant development prospects in lightweight offshore converters. However, the AC/DC-side interaction between the DR and its cascaded system can easily cause oscillation. Impedance analysis is fundamental for studying the stability of cascaded systems. Based on harmonic linearization, this paper derives a frequency-domain small signal model that includes the DR’s improved switching function and commutation process. Considering the cascaded system impedances and commutation disturbance, the frequency coupling mechanism in the DR’s AC sequence impedance is analyzed. Subsequently, a detailed AC/DC-side impedance model of the DR is established, using an impedance matrix form to uniformly model both AC and DC sides, which can connect with the impedance matrix of multi-harmonic response systems. The results indicate that commutation disturbance and frequency coupling significantly affect the DR’s impedance characteristics in the mid and low frequency bands. Finally, the correctness of the DR’s AC/DC-side impedance model is verified through Matlab/Simulink simulation.

Shandong University (CN), China Southern Power Grid (China) (CN), Power Grid Corporation (India) (IN)
Openalex Percentile: Top 76%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of DR’s AC/DC-Side Impedance Modeling Based on Harmonic Linearization — H. J. Wang, Zhijie Liu, et al. · (2025) | TGRS Research Map | TGRS