Numerical simulation studies regarding the workers’ radiofrequency exposure monitoring using wearable multi-location measurement system

The simulation study was to examine the effectiveness of reducing a discrepancy between parameters of unperturbed radiofrequency electromagnetic field (EMF) exposure in the work environment and results of workers exposure measurements using body-worn measurement systems, through performing simultaneous multi sensor (multilocation) measurements by sensors worn at various body locations and subsequent averaging of the results of such measurements.The obtained results revealed that the discrepancy in the outcome of EMF exposure assessments (the value of E-field strength normalized to the parameters of unperturbed E-field) coming from body-worn measurement system (delivering the parameters of EMF disturbed by the body of user wearing this system) may be significantly reduced by using a distributed (multilocation) measurement system.When using the three-point system with one of sensors on the helmet, the lowest discrepancy in the results of exposure evaluation using body-worn system is in case of location of other sensors on the chest and waist.

Authors

Publication Details

Published
2025-01-01
DOI
https://doi.org/10.46620/ursiaprasc25/xnum5187
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical simulation studies regarding the workers’ radiofrequency exposure monitoring using wearable multi-location measurement system

Krzysztof Gryz, Jolanta Karpowicz, Patryk Zradziński
Engineering Applied Research
article

Numerical simulation studies regarding the workers’ radiofrequency exposure monitoring using wearable multi-location measurement system

Krzysztof Gryz, Jolanta Karpowicz, Patryk Zradziński
article en

Abstract

The simulation study was to examine the effectiveness of reducing a discrepancy between parameters of unperturbed radiofrequency electromagnetic field (EMF) exposure in the work environment and results of workers exposure measurements using body-worn measurement systems, through performing simultaneous multi sensor (multilocation) measurements by sensors worn at various body locations and subsequent averaging of the results of such measurements.The obtained results revealed that the discrepancy in the outcome of EMF exposure assessments (the value of E-field strength normalized to the parameters of unperturbed E-field) coming from body-worn measurement system (delivering the parameters of EMF disturbed by the body of user wearing this system) may be significantly reduced by using a distributed (multilocation) measurement system.When using the three-point system with one of sensors on the helmet, the lowest discrepancy in the results of exposure evaluation using body-worn system is in case of location of other sensors on the chest and waist.

Openalex Percentile: Top 74%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.