Mechanical Removal of Migrated Onyx18 Due to Rupture of a Detachable-Tip Microcatheter During Arteriovenous Malformation Embolization

The rupture of a microcatheter leading to the spillage of ethylene vinyl alcohol copolymer (EVOH), specifically Onyx, though infrequent, can give rise to fatal complications. This case report elucidates the accidental migration of Onyx18 into the middle cerebral artery (MCA) and anterior cerebral artery (ACA) due to a ruptured microcatheter. The migration was successfully treated using an aspiration catheter and a Solitaire AB stent. Potential causes for microcatheter rupture include substandard microcatheter quality, prolonged injection intervals, inadequate Onyx mixing before injection, and extended syringe retention in a fixed position. Prompt identification and immediate embolus removal intervention are pivotal measures for curtailing severe complications.

Authors

Institutions

Publication Details

Journal
Neurology India
Published
2025-09-01
DOI
https://doi.org/10.4103/neurol-india.neurol-india-d-23-00681
Primary Topic
Vascular Malformations Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical Removal of Migrated Onyx18 Due to Rupture of a Detachable-Tip Microcatheter During Arteriovenous Malformation Embolization

Ting Wang, Jian Wang, Chaohua Wang, Fayun Hu
Neurology India
Vascular Malformations Diagnosis and Treatment
article

Mechanical Removal of Migrated Onyx18 Due to Rupture of a Detachable-Tip Microcatheter During Arteriovenous Malformation Embolization

Ting Wang, Jian Wang, Chaohua Wang, Fayun Hu
article en

Abstract

The rupture of a microcatheter leading to the spillage of ethylene vinyl alcohol copolymer (EVOH), specifically Onyx, though infrequent, can give rise to fatal complications. This case report elucidates the accidental migration of Onyx18 into the middle cerebral artery (MCA) and anterior cerebral artery (ACA) due to a ruptured microcatheter. The migration was successfully treated using an aspiration catheter and a Solitaire AB stent. Potential causes for microcatheter rupture include substandard microcatheter quality, prolonged injection intervals, inadequate Onyx mixing before injection, and extended syringe retention in a fixed position. Prompt identification and immediate embolus removal intervention are pivotal measures for curtailing severe complications.

Neurology IndiaVol. 73(5)
Sichuan University (CN), West China Hospital of Sichuan University (CN)
Openalex Percentile: Top 65%
Vascular Malformations Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.