Agreement between mean weighted skin temperature formulas during exercise

There are many formulas to calculate mean weighted skin temperature (T<sub>mws</sub>) with little evidence for their agreement with each other. This investigation assessed the agreement of five common T<sub>mws</sub> formulas (≤7 sites) with a 12-site formula (Hardy-DuBois 12-site, HDB12). It was hypothesized that a formula with more measurement sites (Hardy-Dubois 7-site, HDB7) would have more agreement during steady-state exercise in moderate (20°C) and warm (30°C) conditions. Ten well-trained male participants (age: 37 ± 12 yr, height: 178 ± 7 cm, mass: 76 ± 9 kg, body fat: 8 ± 2%, V̇o<sub>2peak</sub>: 66 ± 10 mL/kg/min) cycled at 55% of peak oxygen uptake for 60 min. The T<sub>mws</sub> were calculated for HDB12, HDB7, Palmes/Park 6-site (PP6), Teichner 6-site (TEI6), Ramanathan 4-site (RAM4), and Burton 3-site (BTN3) formulas. Good agreement was determined when the mean bias, mean absolute error (MAE), or root mean squared error (RMSE) was ≤0.5°C or the limits of agreement (LOA) were ≤1.0°C. The T<sub>mws</sub> formulas were in better agreement with HDB12 in warm compared with moderate conditions. The best performing formulas were RAM4, BRT3, and TEI6; mean bias was low in RAM4 (moderate: 0.2°C; warm: 0.1°C) and BRT3 (moderate: 0.1°C; warm: 0.0°C) and RMSE was low in TEI6 (moderate: 0.6°C; warm: 0.4°C) compared with the others. The large deviation in torso skin temperature for HDB7 (moderate: -2.0°C; warm: -1.6°C) resulted in consistent underestimation of HDB12 (mean bias, moderate: -0.8°C; warm: -0.5°C). Due to its popularity, the four-site RAM4 is acceptable for cycling in 20°C and 30°C conditions, when a 12-site formula is not feasible.<b>NEW & NOTEWORTHY</b> This investigation is the first to show T<sub>mws</sub> formula agreement during exercise in moderate (20°C) and warm (30°C) environments. This study uniquely contributes to the present knowledge by showing better agreement between all formulas and the criterion in the 30°C environment than in the 20°C environment during exercise. This study supports the prevalent use of the Ramanathan formula currently in research.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physiology
Published
2025-09-12
DOI
https://doi.org/10.1152/japplphysiol.00445.2025
Citations
1
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
1.16
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Agreement between mean weighted skin temperature formulas during exercise

Nathan E. Bartman, Stephen S. Cheung, Naoto Fujii, Toby Mündel et al.
1 citations
Journal of Applied Physiology
Thermoregulation and physiological responses
1.16
article

Agreement between mean weighted skin temperature formulas during exercise

Nathan E. Bartman, Stephen S. Cheung, Naoto Fujii, Toby Mündel, Tatsuro Amano, Nicole E. Moyen
article en
1 citations

Abstract

There are many formulas to calculate mean weighted skin temperature (T<sub>mws</sub>) with little evidence for their agreement with each other. This investigation assessed the agreement of five common T<sub>mws</sub> formulas (≤7 sites) with a 12-site formula (Hardy-DuBois 12-site, HDB12). It was hypothesized that a formula with more measurement sites (Hardy-Dubois 7-site, HDB7) would have more agreement during steady-state exercise in moderate (20°C) and warm (30°C) conditions. Ten well-trained male participants (age: 37 ± 12 yr, height: 178 ± 7 cm, mass: 76 ± 9 kg, body fat: 8 ± 2%, V̇o<sub>2peak</sub>: 66 ± 10 mL/kg/min) cycled at 55% of peak oxygen uptake for 60 min. The T<sub>mws</sub> were calculated for HDB12, HDB7, Palmes/Park 6-site (PP6), Teichner 6-site (TEI6), Ramanathan 4-site (RAM4), and Burton 3-site (BTN3) formulas. Good agreement was determined when the mean bias, mean absolute error (MAE), or root mean squared error (RMSE) was ≤0.5°C or the limits of agreement (LOA) were ≤1.0°C. The T<sub>mws</sub> formulas were in better agreement with HDB12 in warm compared with moderate conditions. The best performing formulas were RAM4, BRT3, and TEI6; mean bias was low in RAM4 (moderate: 0.2°C; warm: 0.1°C) and BRT3 (moderate: 0.1°C; warm: 0.0°C) and RMSE was low in TEI6 (moderate: 0.6°C; warm: 0.4°C) compared with the others. The large deviation in torso skin temperature for HDB7 (moderate: -2.0°C; warm: -1.6°C) resulted in consistent underestimation of HDB12 (mean bias, moderate: -0.8°C; warm: -0.5°C). Due to its popularity, the four-site RAM4 is acceptable for cycling in 20°C and 30°C conditions, when a 12-site formula is not feasible.<b>NEW & NOTEWORTHY</b> This investigation is the first to show T<sub>mws</sub> formula agreement during exercise in moderate (20°C) and warm (30°C) environments. This study uniquely contributes to the present knowledge by showing better agreement between all formulas and the criterion in the 30°C environment than in the 20°C environment during exercise. This study supports the prevalent use of the Ramanathan formula currently in research.

Journal of Applied PhysiologyVol. 139(4)
University of Tsukuba (JP), Brock University (CA), HealthInsight (US), Massey University (NZ), Niigata University (JP)
Openalex Percentile: Top 18%
Thermoregulation and physiological responses
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.