From lab to pilot: Predicting and validating caffeine and DEET removal from treated greywater using response surface methodology and artificial neural networks

• ANN and RSM models predict removal efficiency based on lab-scale experiments. • ANN outperformed RSM for caffeine; both performed well for DEET removal predictions. • Caffeine concentration had the highest influence on caffeine removal. • DOC concentration had the highest influence of DEET removal. • ANN performed better in predicting caffeine and DEET removal for unseen pilot tests. Greywater, a valuable resource in water-scarce regions, contains organic micropollutants (OMPs) from household chemicals, pharmaceuticals and personal care products. Ozonation is a promising technology for removing these OMPs, enabling the safe reuse of treated greywater (TGW) for irrigation. In this study, TGW was analyzed and found to contain high levels of caffeine and N, N‑diethyl‑meta-toluamide (DEET). Laboratory-scale ozonation experiments were conducted using the Box-Behnken design, varying ozone dosage, dissolved organic carbon (DOC), and pollutant concentrations. Response surface methodology (RSM) and artificial neural network (ANN) models were developed to examine the effects of these variables and to compare the prediction of removal efficiency (RE) for these compounds. The models were validated with pilot-scale ozonation experiments using treated greywater. The ANN model was more effective than RSM in predicting caffeine RE, while both models showed comparable performance for DEET, with RSM yielding lower relative errors. Sensitivity analysis revealed that caffeine RE was most influenced by its initial concentration, whereas DEET RE was primarily affected by DOC levels, followed by ozone dosage. The pilot study results indicated an effective removal efficiency of caffeine (80 %) and DEET (91 %) at an ozone dosage of 2 mg/L. The ANN model demonstrated better prediction and trend capturing than the RSM model when subjected to pilot-scale data. The study demonstrated that models developed from lab-scale data, particularly ANN, can be effectively applied to design, optimize, and control pilot-scale ozonation experiments.

Authors

Institutions

Publication Details

Journal
Chemical Engineering and Processing - Process Intensification
Published
2025-09-09
DOI
https://doi.org/10.1016/j.cep.2025.110542
Primary Topic
Wastewater Treatment and Reuse
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From lab to pilot: Predicting and validating caffeine and DEET removal from treated greywater using response surface methodology and artificial neural networks

Simjo Simson, Mumu Aktar, Jasir Jawad, Jayaprakash Saththasivam et al.
Chemical Engineering and Processing - Process Intensification
Wastewater Treatment and Reuse
article

From lab to pilot: Predicting and validating caffeine and DEET removal from treated greywater using response surface methodology and artificial neural networks

Simjo Simson, Mumu Aktar, Jasir Jawad, Jayaprakash Saththasivam, Tricia Gomez
article en

Abstract

• ANN and RSM models predict removal efficiency based on lab-scale experiments. • ANN outperformed RSM for caffeine; both performed well for DEET removal predictions. • Caffeine concentration had the highest influence on caffeine removal. • DOC concentration had the highest influence of DEET removal. • ANN performed better in predicting caffeine and DEET removal for unseen pilot tests. Greywater, a valuable resource in water-scarce regions, contains organic micropollutants (OMPs) from household chemicals, pharmaceuticals and personal care products. Ozonation is a promising technology for removing these OMPs, enabling the safe reuse of treated greywater (TGW) for irrigation. In this study, TGW was analyzed and found to contain high levels of caffeine and N, N‑diethyl‑meta-toluamide (DEET). Laboratory-scale ozonation experiments were conducted using the Box-Behnken design, varying ozone dosage, dissolved organic carbon (DOC), and pollutant concentrations. Response surface methodology (RSM) and artificial neural network (ANN) models were developed to examine the effects of these variables and to compare the prediction of removal efficiency (RE) for these compounds. The models were validated with pilot-scale ozonation experiments using treated greywater. The ANN model was more effective than RSM in predicting caffeine RE, while both models showed comparable performance for DEET, with RSM yielding lower relative errors. Sensitivity analysis revealed that caffeine RE was most influenced by its initial concentration, whereas DEET RE was primarily affected by DOC levels, followed by ozone dosage. The pilot study results indicated an effective removal efficiency of caffeine (80 %) and DEET (91 %) at an ozone dosage of 2 mg/L. The ANN model demonstrated better prediction and trend capturing than the RSM model when subjected to pilot-scale data. The study demonstrated that models developed from lab-scale data, particularly ANN, can be effectively applied to design, optimize, and control pilot-scale ozonation experiments.

Chemical Engineering and Processing - Process IntensificationVol. 218
Hamad bin Khalifa University (QA), Qatar Foundation (QA)
Openalex Percentile: Top 70%
Wastewater Treatment and Reuse
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.