Electron density measurement in low-density plasma of electrical wire explosion using a Shack–Hartmann wavefront sensor

Measuring the electron density of low-density plasma has long been a challenge, as traditional diagnostic techniques often lack sufficient sensitivity or spatial resolution. To address this, this paper presents an electron density diagnostic method for corona plasma generated by electrical wire explosion, based on a Shack-Hartmann wavefront sensor. The diagnostic system integrates an 8 ns, 532 nm nanosecond pulsed laser, a 400 mm focal length lens array, and a high-resolution charge-coupled device camera. By integrating the proposed neural network methods with micro-lens optical simulations, we achieved sub-pixel-level centroid localization of the focal spot, reducing shift errors by 21% compared to conventional convolutional neural network methods and achieving sub-pixel accuracy with an error of only 0.25 pixels. The theoretical sensitivity of the system reaches 2 × 1015 cm-2. In experiments using a silver-wire load under pre-pulse conditions, this diagnostic technique demonstrated strong agreement with laser interferometry results in high density regions. In low-density regions, the electron density measured at 4.4 mm from the wire axis reached a minimum of 2.2 × 1016 cm-2, offering a broader spatial range for plasma electron density diagnostics compared to laser interferometry. This method effectively captured the electron density distribution of the corona plasma formed under pre-pulse conditions. Future work will focus on further optimizing the experimental system to reduce sources of error and extending the application of this technique to large-scale pulsed power facilities for diagnosing the formation and parameter distribution of low-density electrode plasmas.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-09-01
DOI
https://doi.org/10.1063/5.0270669
Primary Topic
Traumatic Ocular and Foreign Body Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electron density measurement in low-density plasma of electrical wire explosion using a Shack–Hartmann wavefront sensor

Zhenyu Wang, Wei Wang, Jian Wu, Huantong Shi et al.
Review of Scientific Instruments
Traumatic Ocular and Foreign Body Injuries
article

Electron density measurement in low-density plasma of electrical wire explosion using a Shack–Hartmann wavefront sensor

Zhenyu Wang, Wei Wang, Jian Wu, Huantong Shi, Xingwen Li, Yiming Zhao, Yang Li, Zhiyuan Jiang, Aici Qiu
article en

Abstract

Measuring the electron density of low-density plasma has long been a challenge, as traditional diagnostic techniques often lack sufficient sensitivity or spatial resolution. To address this, this paper presents an electron density diagnostic method for corona plasma generated by electrical wire explosion, based on a Shack-Hartmann wavefront sensor. The diagnostic system integrates an 8 ns, 532 nm nanosecond pulsed laser, a 400 mm focal length lens array, and a high-resolution charge-coupled device camera. By integrating the proposed neural network methods with micro-lens optical simulations, we achieved sub-pixel-level centroid localization of the focal spot, reducing shift errors by 21% compared to conventional convolutional neural network methods and achieving sub-pixel accuracy with an error of only 0.25 pixels. The theoretical sensitivity of the system reaches 2 × 1015 cm-2. In experiments using a silver-wire load under pre-pulse conditions, this diagnostic technique demonstrated strong agreement with laser interferometry results in high density regions. In low-density regions, the electron density measured at 4.4 mm from the wire axis reached a minimum of 2.2 × 1016 cm-2, offering a broader spatial range for plasma electron density diagnostics compared to laser interferometry. This method effectively captured the electron density distribution of the corona plasma formed under pre-pulse conditions. Future work will focus on further optimizing the experimental system to reduce sources of error and extending the application of this technique to large-scale pulsed power facilities for diagnosing the formation and parameter distribution of low-density electrode plasmas.

Review of Scientific InstrumentsVol. 96(9)
Northwest Institute of Nuclear Technology (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 64%
Traumatic Ocular and Foreign Body Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.