Force-Sensitive Resistors for Detecting Peripheral IV Failure

Peripheral intravenous catheters fail frequently, with some estimates of failure rates as high as 50% globally. In this letter, the potential for using force-sensitive resistors (FSRs) for the detection of swelling caused by infiltration or extravasation associated with peripheral IV failures (PIVIEs) is explored. Silicone models with elastic moduli and shape consistent with that experienced by body tissue during PIVIEs were integrated into a testbed with a layer of artificial skin, transparent film dressing, FSR, and bandage. The response of an FSR manufactured by Tekscan with a standard response range up to 1 lb (4.4 N) was measured for each combination of three swelling heights (8, 12, and 18 mm) and elastic moduli (∼390, ∼490, and ∼540 kPa) and compared to the response of a precise force sensor (SingleTact 1.0 N) to determine the feasibility of using FSRs for detecting PIVIEs. Results show that the FSR resistance consistently decreases with increasing swelling height for a given elastic modulus. The coefficient of variability in the force-sensitive resistor output varies from 0.60% to 31.3% with the lowest variability occurring for the smallest amount of swelling. When filtering is introduced to remove outlying events in the FSR response, however, the range of variability drops to between 0.42% and 10.2%. While these experiments are preliminary, they nevertheless demonstrate the potential for using FSRs in single-use, disposable patches for monitoring IVs and detecting failure due to infiltration and swelling.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Letters
Published
2025-09-09
DOI
https://doi.org/10.1109/lsens.2025.3605173
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Force-Sensitive Resistors for Detecting Peripheral IV Failure

Lorenzo Guio, Gregory C. Valentine, Denise Wilson
IEEE Sensors Letters
Sensor Technology and Measurement Systems
article

Force-Sensitive Resistors for Detecting Peripheral IV Failure

Lorenzo Guio, Gregory C. Valentine, Denise Wilson
article en

Abstract

Peripheral intravenous catheters fail frequently, with some estimates of failure rates as high as 50% globally. In this letter, the potential for using force-sensitive resistors (FSRs) for the detection of swelling caused by infiltration or extravasation associated with peripheral IV failures (PIVIEs) is explored. Silicone models with elastic moduli and shape consistent with that experienced by body tissue during PIVIEs were integrated into a testbed with a layer of artificial skin, transparent film dressing, FSR, and bandage. The response of an FSR manufactured by Tekscan with a standard response range up to 1 lb (4.4 N) was measured for each combination of three swelling heights (8, 12, and 18 mm) and elastic moduli (∼390, ∼490, and ∼540 kPa) and compared to the response of a precise force sensor (SingleTact 1.0 N) to determine the feasibility of using FSRs for detecting PIVIEs. Results show that the FSR resistance consistently decreases with increasing swelling height for a given elastic modulus. The coefficient of variability in the force-sensitive resistor output varies from 0.60% to 31.3% with the lowest variability occurring for the smallest amount of swelling. When filtering is introduced to remove outlying events in the FSR response, however, the range of variability drops to between 0.42% and 10.2%. While these experiments are preliminary, they nevertheless demonstrate the potential for using FSRs in single-use, disposable patches for monitoring IVs and detecting failure due to infiltration and swelling.

IEEE Sensors LettersVol. 9(10)
University of Washington (US)
Openalex Percentile: Top 72%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.