Testing compact, fused silica resonator based inertial sensors in a gravitational wave detector prototype facility

Abstract Future gravitational wave observatories require significant advances in all aspects of their seismic isolation; inertial sensors being a pressing example. Inertial sensors using gram-scale high mechanical Q factor ( Q ) glass resonators combined with compact interferometric readout are promising alternatives to kilogram-scale conventional inertial sensors. We have produced fused silica resonators suitable for low frequency inertial sensing and demonstrated that Q s of over 150 000 are possible. One resonator we produced was combined with a homodyne quadrature interferometer (HoQI) to read out the test mass displacement to form an inertial sensor. This is the first time a HoQI was used with a high Q resonator. The resulting sensor was tested against other commercial, kilogram scale inertial sensors at the AEI 10 m Prototype facility. Despite the dynamic range challenges induced by the test mass motion, we can match the excellent noise floors HoQIs have achieved so far with slow-moving or stationary test masses, showing HoQIs as an excellent candidate for the readout of such sensors. We evaluate the setup as an inertial sensor, showing the best performance demonstrated by any gram-scale sensor to date, with comparable sensitivity to the significantly bulkier sensors used in gravitational wave detectors today. These sensors’ compact size, self-calibration, and vacuum compatibility make them ideal candidates for the inertial sensing requirements in future gravitational wave detectors.

Authors

Institutions

Publication Details

Journal
Classical and Quantum Gravity
Published
2025-09-09
DOI
https://doi.org/10.1088/1361-6382/adff34
Primary Topic
Geophysics and Sensor Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Testing compact, fused silica resonator based inertial sensors in a gravitational wave detector prototype facility

Pratik Sarkar, Sebastian Risse, D. S. Wu, Harald Lück et al.
Classical and Quantum Gravity
Geophysics and Sensor Technology
article

Testing compact, fused silica resonator based inertial sensors in a gravitational wave detector prototype facility

Pratik Sarkar, Sebastian Risse, D. S. Wu, Harald Lück, G Chiarini, Carolin Rothhardt, A. Basalaev, J von Wrangel, S. L. Kranzhoff, Pascal Birckigt, S. M. Koehlenbeck, J. J. Carter, F. Khan, Gilbert Leibeling, M Carlassara, Satoru Takano, J. Lehmann, S. Al-Kershi
article en

Abstract

Abstract Future gravitational wave observatories require significant advances in all aspects of their seismic isolation; inertial sensors being a pressing example. Inertial sensors using gram-scale high mechanical Q factor ( Q ) glass resonators combined with compact interferometric readout are promising alternatives to kilogram-scale conventional inertial sensors. We have produced fused silica resonators suitable for low frequency inertial sensing and demonstrated that Q s of over 150 000 are possible. One resonator we produced was combined with a homodyne quadrature interferometer (HoQI) to read out the test mass displacement to form an inertial sensor. This is the first time a HoQI was used with a high Q resonator. The resulting sensor was tested against other commercial, kilogram scale inertial sensors at the AEI 10 m Prototype facility. Despite the dynamic range challenges induced by the test mass motion, we can match the excellent noise floors HoQIs have achieved so far with slow-moving or stationary test masses, showing HoQIs as an excellent candidate for the readout of such sensors. We evaluate the setup as an inertial sensor, showing the best performance demonstrated by any gram-scale sensor to date, with comparable sensitivity to the significantly bulkier sensors used in gravitational wave detectors today. These sensors’ compact size, self-calibration, and vacuum compatibility make them ideal candidates for the inertial sensing requirements in future gravitational wave detectors.

Classical and Quantum GravityVol. 42(18)
Leibniz University Hannover (DE), Maastricht University (NL), National Institute for Subatomic Physics (NL), Fraunhofer Institute for Applied Optics and Precision Engineering (DE), Max Planck Institute for Gravitational Physics (DE), Stanford University (US)
Openalex Percentile: Top 70%
Geophysics and Sensor Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.