The Safety and Performance of a Novel Extracorporeal Membrane Oxygenation Device in a Long-Term Ovine Model

Since extracorporeal membrane oxygenation (ECMO) is primarily used for patients in a high-risk state and is an invasive procedure, its unique application scenarios make it difficult to recruit suitable cases for clinical trials. Therefore, large animal models have become one of the most important models for preclinical evaluation of the safety and effectiveness of ECMO. This study aims to assess the safety and performance of a novel portable ECMO device with Small-tail Han sheep. Fifteen sheep were divided into a test group (LIFEMOTION, Chinabridge, Shenzhen, China) and control group (NOVALUNG XLUNG kit 230, Xonis, Heilbronn, Germany) with veno-venous ECMO (VV-ECMO) and veno-arterial ECMO (VA-ECMO) modes. Tracheal intubation, arteriovenous access, and ECMO support were performed. Vital signs and blood laboratory tests of the subjects were monitored and recorded. The main organs were examined pathologically at the end of day fourteen. The serum protein expression profile was analyzed by protein quantification techniques. All sheep were successfully weaned from ECMO without transfusion or cannula complications. No significant differences were observed between the two groups in terms of vital signs, oxygenation, hemodynamic stability, and physiological function (<i>p</i> > 0.05). According to the serum protein expression profile, no significant biomarkers associated with ECMO clinical complications were identified. The LIFEMOTION ECMO device demonstrated good safety and efficacy.

Authors

Institutions

Publication Details

Journal
Advances in respiratory medicine
Published
2025-09-09
DOI
https://doi.org/10.3390/arm93050034
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Safety and Performance of a Novel Extracorporeal Membrane Oxygenation Device in a Long-Term Ovine Model

Yalun Guan, Shuhua Liu, Jia Huang, Shi Liang et al.
Advances in respiratory medicine
Mechanical Circulatory Support Devices
article

The Safety and Performance of a Novel Extracorporeal Membrane Oxygenation Device in a Long-Term Ovine Model

Yalun Guan, Shuhua Liu, Jia Huang, Shi Liang, Lei Cai, Yunfeng Li, Ge Li, Hongzhou Lu, Yu Zhang, Yun Li, Hongbin Gao, Yongchao Li, Zhongqiang Huang, Summer Xiatian Li
article en

Abstract

Since extracorporeal membrane oxygenation (ECMO) is primarily used for patients in a high-risk state and is an invasive procedure, its unique application scenarios make it difficult to recruit suitable cases for clinical trials. Therefore, large animal models have become one of the most important models for preclinical evaluation of the safety and effectiveness of ECMO. This study aims to assess the safety and performance of a novel portable ECMO device with Small-tail Han sheep. Fifteen sheep were divided into a test group (LIFEMOTION, Chinabridge, Shenzhen, China) and control group (NOVALUNG XLUNG kit 230, Xonis, Heilbronn, Germany) with veno-venous ECMO (VV-ECMO) and veno-arterial ECMO (VA-ECMO) modes. Tracheal intubation, arteriovenous access, and ECMO support were performed. Vital signs and blood laboratory tests of the subjects were monitored and recorded. The main organs were examined pathologically at the end of day fourteen. The serum protein expression profile was analyzed by protein quantification techniques. All sheep were successfully weaned from ECMO without transfusion or cannula complications. No significant differences were observed between the two groups in terms of vital signs, oxygenation, hemodynamic stability, and physiological function (<i>p</i> > 0.05). According to the serum protein expression profile, no significant biomarkers associated with ECMO clinical complications were identified. The LIFEMOTION ECMO device demonstrated good safety and efficacy.

Advances in respiratory medicineVol. 93(5)
Guangzhou Experimental Station (CN), Guangdong Laboratory Animals Monitoring Institute (CN), Shenzhen Bao'an District People's Hospital (CN), Shenzhen Third People’s Hospital (CN)
China Postdoctoral Science Foundation
Openalex Percentile: Top 77%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.