Construction of a High-Precision Underwater 3D Reconstruction System Based on Line Laser

This study presents a high-precision underwater 3D reconstruction system based on rotating laser scanning. The system adopts a modeling framework that combines air-based camera calibration with refraction compensation. A five-stage image preprocessing pipeline, followed by an adaptive locally weighted centroid (ALWC) algorithm, is employed to extract the laser stripe centerline with high accuracy. In addition, a synchronized feature extraction-based joint calibration method is introduced to simultaneously calibrate the light plane and the rotation axis. Resolution evaluation experiments demonstrate that the system achieves a spatial resolution of better than 0.6 mm in clear water at a distance of 1 m, and approximately 0.8 mm in turbid water conditions of 6 Nephelometric Turbidity Units (NTU), thereby verifying its reconstruction accuracy and robustness under varying water clarity.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-09-09
DOI
https://doi.org/10.3390/s25185615
Citations
1
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
1.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Construction of a High-Precision Underwater 3D Reconstruction System Based on Line Laser

Yueping Zeng, Maohang Qiu, Hongyang Xu, Xiaoping Wang
1 citations
Sensors
Optical measurement and interference techniques
1.28
article

Construction of a High-Precision Underwater 3D Reconstruction System Based on Line Laser

Yueping Zeng, Maohang Qiu, Hongyang Xu, Xiaoping Wang
article en
1 citations

Abstract

This study presents a high-precision underwater 3D reconstruction system based on rotating laser scanning. The system adopts a modeling framework that combines air-based camera calibration with refraction compensation. A five-stage image preprocessing pipeline, followed by an adaptive locally weighted centroid (ALWC) algorithm, is employed to extract the laser stripe centerline with high accuracy. In addition, a synchronized feature extraction-based joint calibration method is introduced to simultaneously calibrate the light plane and the rotation axis. Resolution evaluation experiments demonstrate that the system achieves a spatial resolution of better than 0.6 mm in clear water at a distance of 1 m, and approximately 0.8 mm in turbid water conditions of 6 Nephelometric Turbidity Units (NTU), thereby verifying its reconstruction accuracy and robustness under varying water clarity.

SensorsVol. 25(18)
Zhejiang Ocean University (CN), Zhejiang University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 16%
Optical measurement and interference techniques
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.