Analysis of AC and DC Interference in One Buried Gas Pipeline

The complex interference created by several sources for pipelines has not been sufficiently studied. In this study, four types of interference sources were monitored and analyzed. AC voltage monitoring, DC potential monitoring, current density monitoring, and excavation observation and measurement for test pieces and the decouplers were employed to assess the AC/DC interference of one real buried pipeline in situ. The peak value obtained from the second measurement at Pile 33 decreased from 1341.8 V to 143.7 V, indicating that the 1341.8 V in the first measurement may be caused by a sudden grounding of the electrode, while the 143.7 V may be caused by the normal induced voltage. The most negative DC interference potential between the pipeline and the Cu/CuSO4 reference electrode was −11.946 V. The most positive DC interference potential between the pipeline and the Cu/CuSO4 reference electrode was 4.862 V. Pile 3 had a maximum DC current density of 240 mA/m2, and Pile 4 had a maximum AC current density of 0.615 A/m2. After excavating the test piece at Pile 3, the point with maximum DC interference, there were obvious pitting corrosion characteristics, and the corrosion products were mainly γ-FeOOH and Fe3O4. It indicated that the coupling of long-term higher positive DC current density or (DC potential) and short-term higher transient AC voltage or (AC current density) may lead to corrosion. After excavating the test piece at the point with maximum AC interference, namely, Pile 4, there were no significant AC or DC corrosion characteristics. This finding suggested that the combination of long-term low AC current voltage or (low AC current density) and long-term more negative low DC current density or (DC potential) did not result in obvious corrosion. The decouplers in this measurement significantly reduced AC interference above 2 V, but the isolation of transient AC shocks and AC interference below 2 V were not significant. During analysis of AC and DC interference, in addition to considering the value of the interference, the duration time of the interference was also an important factor. Instantaneous sharp peaks cannot represent the long-term average voltage or potential current density. The average value should be used as the main basis for judgement, and the instantaneous value should be used as the secondary basis for judgement.

Authors

Institutions

Publication Details

Journal
Coatings
Published
2025-09-09
DOI
https://doi.org/10.3390/coatings15091056
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of AC and DC Interference in One Buried Gas Pipeline

Haishan Liu, Jianqing Liu, Wang Zai-feng, Jie Zhang et al.
Coatings
Non-Destructive Testing Techniques
article

Analysis of AC and DC Interference in One Buried Gas Pipeline

Haishan Liu, Jianqing Liu, Wang Zai-feng, Jie Zhang, Yang Liu, Yu Ding
article en

Abstract

The complex interference created by several sources for pipelines has not been sufficiently studied. In this study, four types of interference sources were monitored and analyzed. AC voltage monitoring, DC potential monitoring, current density monitoring, and excavation observation and measurement for test pieces and the decouplers were employed to assess the AC/DC interference of one real buried pipeline in situ. The peak value obtained from the second measurement at Pile 33 decreased from 1341.8 V to 143.7 V, indicating that the 1341.8 V in the first measurement may be caused by a sudden grounding of the electrode, while the 143.7 V may be caused by the normal induced voltage. The most negative DC interference potential between the pipeline and the Cu/CuSO4 reference electrode was −11.946 V. The most positive DC interference potential between the pipeline and the Cu/CuSO4 reference electrode was 4.862 V. Pile 3 had a maximum DC current density of 240 mA/m2, and Pile 4 had a maximum AC current density of 0.615 A/m2. After excavating the test piece at Pile 3, the point with maximum DC interference, there were obvious pitting corrosion characteristics, and the corrosion products were mainly γ-FeOOH and Fe3O4. It indicated that the coupling of long-term higher positive DC current density or (DC potential) and short-term higher transient AC voltage or (AC current density) may lead to corrosion. After excavating the test piece at the point with maximum AC interference, namely, Pile 4, there were no significant AC or DC corrosion characteristics. This finding suggested that the combination of long-term low AC current voltage or (low AC current density) and long-term more negative low DC current density or (DC potential) did not result in obvious corrosion. The decouplers in this measurement significantly reduced AC interference above 2 V, but the isolation of transient AC shocks and AC interference below 2 V were not significant. During analysis of AC and DC interference, in addition to considering the value of the interference, the duration time of the interference was also an important factor. Instantaneous sharp peaks cannot represent the long-term average voltage or potential current density. The average value should be used as the main basis for judgement, and the instantaneous value should be used as the secondary basis for judgement.

CoatingsVol. 15(9)
China National Offshore Oil Corporation (China) (CN), Chinese Academy of Sciences (CN), Institute of Oceanology (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China, Natural Science Foundation of Shandong Province
Openalex Percentile: Top 75%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.