Evaluation of mean glandular dose in relation to breast density in digital mammography

Abstract Background Mammography is considered an ideal tool for breast cancer screening due to its proven effectiveness, which has led to its widespread use as the primary imaging modality for early detection. In addition, mammography is associated with a radiation dose represented as the mean glandular dose (MGD), resulting in a risk of developing breast cancer. However, efforts are being made to reduce this radiation dose. The objective of this study was to identify the MGD during screening mammography based on breast densities and investigate the correlation between MGD and BMI, breast thickness, and compression force in digital mammography. A total of 176 participants, exposed to two basic projections cranio-caudal (CC) projection and medio-lateral oblique (MLO) projection. Breast density was classified according to the guidelines by the American College of Radiology as Breast Imaging Reporting and Data System. Results Mean glandular dose (MGD) increased progressively with breast density, ranging from 8.80 ± 2.74 mGy in Category A (fatty) to 11.27 ± 3.43 mGy in Category D (extremely dense). MLO projections consistently showed higher MGD than CC views. A strong positive correlation was observed between breast thickness and MGD ( r = 0.80 in left MLO). MGD also showed a moderate positive correlation with BMI ( r = 0.44), while compression force had minimal impact. Conclusion Breast density, breast thickness, and BMI significantly influence the mean glandular dose in digital mammography. High breast density and thickness, along with increased BMI, are associated with elevated radiation doses, highlighting the need for personalized dose optimization to ensure effective and safe breast cancer screening.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Published
2025-09-09
DOI
https://doi.org/10.1186/s43055-025-01586-y
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of mean glandular dose in relation to breast density in digital mammography

Fatemeh Amiri, Sneha Ravichandran, Samir Mustaffa Paruthikunnan, Winniecia Dkhar et al.
The Egyptian Journal of Radiology and Nuclear Medicine
Digital Radiography and Breast Imaging
article

Evaluation of mean glandular dose in relation to breast density in digital mammography

Fatemeh Amiri, Sneha Ravichandran, Samir Mustaffa Paruthikunnan, Winniecia Dkhar, Rajagopal Kadavigere, Abhimanyu Pradhan, Bilga Jacob, Neil Abraham Barnes
article en

Abstract

Abstract Background Mammography is considered an ideal tool for breast cancer screening due to its proven effectiveness, which has led to its widespread use as the primary imaging modality for early detection. In addition, mammography is associated with a radiation dose represented as the mean glandular dose (MGD), resulting in a risk of developing breast cancer. However, efforts are being made to reduce this radiation dose. The objective of this study was to identify the MGD during screening mammography based on breast densities and investigate the correlation between MGD and BMI, breast thickness, and compression force in digital mammography. A total of 176 participants, exposed to two basic projections cranio-caudal (CC) projection and medio-lateral oblique (MLO) projection. Breast density was classified according to the guidelines by the American College of Radiology as Breast Imaging Reporting and Data System. Results Mean glandular dose (MGD) increased progressively with breast density, ranging from 8.80 ± 2.74 mGy in Category A (fatty) to 11.27 ± 3.43 mGy in Category D (extremely dense). MLO projections consistently showed higher MGD than CC views. A strong positive correlation was observed between breast thickness and MGD ( r = 0.80 in left MLO). MGD also showed a moderate positive correlation with BMI ( r = 0.44), while compression force had minimal impact. Conclusion Breast density, breast thickness, and BMI significantly influence the mean glandular dose in digital mammography. High breast density and thickness, along with increased BMI, are associated with elevated radiation doses, highlighting the need for personalized dose optimization to ensure effective and safe breast cancer screening.

The Egyptian Journal of Radiology and Nuclear MedicineVol. 56(1)
Manipal Academy of Higher Education (IN), York Teaching Hospital NHS Foundation Trust (GB)
Openalex Percentile: Top 65%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.