Determination of the Image Quality in Computed Tomography and its Standardisation

X-Ray Computed tomography (XCT) has become an important non-destructive quality assurance technique in industry. Consequently, standards for quality insurance of XCT and on its performance are required to support industrial XCT users for reliable production. This performance is determined by analysis of the quality of the images produced and by the dimensional measurement accuracy achieved for a given XCT parameter setting. Until recently, standards assessed image quality solely in terms of contrast sensitivity and spatial resolution. Detection limits could not be predicted until now. A new term is introduced: The Detail Detection Sensitivity (DDS). It depends on the contrast sensitivity as a function of contrast and noise, and on the spatial resolution. The spatial frequency needs to be implemented into the analysis to consider sensitivity as a function of the size of an indication. The contrast sensitivity is quantified by the Contrast Discrimination Function (CDF) and the spatial resolution by the Modulation Transfer Function (MTF). The numerical DDS is determined for air flaws from the Contrast Detection Diagram (CDD) at 100% contrast. However, some XCT operators prefer visual determinations rather than numerical ones. To face this need, the SensMonCTII project proposes a new Image Quality Indicator (IQI), consisting of a disk with holes of different sizes for visual DDS determination. The project aims to produce a new ISO standard draft providing a practice to evaluate numerically the XCT image quality via MTF, CDF, CDD and DDS, as well as to evaluate visually the DDS from the hole visibility of a disk IQI. The paper does not address the performance of XCT in terms of dimensional measurement accuracy, but focuses on the performance of XCT in terms of image quality. It describes the methodology to evaluate the image quality, including DDS for the first time.

Authors

Institutions

Publication Details

Journal
Journal of Nondestructive Evaluation
Published
2025-09-09
DOI
https://doi.org/10.1007/s10921-025-01266-x
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of the Image Quality in Computed Tomography and its Standardisation

Lionel Gay, Janka Wilbig, Uwe Ewert, Clément Remacha et al.
1 citations
Journal of Nondestructive Evaluation
Advanced X-ray and CT Imaging
0.67
article

Determination of the Image Quality in Computed Tomography and its Standardisation

Lionel Gay, Janka Wilbig, Uwe Ewert, Clément Remacha, Dominik Brouczek, Martin Schwentenwein, Holger R. Roth, Marko Katić, Anne-Françoise Obaton, Nicolas Cochennec, Alain Küng, Simon Burkhard
article en
1 citations

Abstract

X-Ray Computed tomography (XCT) has become an important non-destructive quality assurance technique in industry. Consequently, standards for quality insurance of XCT and on its performance are required to support industrial XCT users for reliable production. This performance is determined by analysis of the quality of the images produced and by the dimensional measurement accuracy achieved for a given XCT parameter setting. Until recently, standards assessed image quality solely in terms of contrast sensitivity and spatial resolution. Detection limits could not be predicted until now. A new term is introduced: The Detail Detection Sensitivity (DDS). It depends on the contrast sensitivity as a function of contrast and noise, and on the spatial resolution. The spatial frequency needs to be implemented into the analysis to consider sensitivity as a function of the size of an indication. The contrast sensitivity is quantified by the Contrast Discrimination Function (CDF) and the spatial resolution by the Modulation Transfer Function (MTF). The numerical DDS is determined for air flaws from the Contrast Detection Diagram (CDD) at 100% contrast. However, some XCT operators prefer visual determinations rather than numerical ones. To face this need, the SensMonCTII project proposes a new Image Quality Indicator (IQI), consisting of a disk with holes of different sizes for visual DDS determination. The project aims to produce a new ISO standard draft providing a practice to evaluate numerically the XCT image quality via MTF, CDF, CDD and DDS, as well as to evaluate visually the DDS from the hole visibility of a disk IQI. The paper does not address the performance of XCT in terms of dimensional measurement accuracy, but focuses on the performance of XCT in terms of image quality. It describes the methodology to evaluate the image quality, including DDS for the first time.

Journal of Nondestructive EvaluationVol. 44(4)
University of Zagreb (HR), Atotech (Germany) (DE), Swiss Federal Institute of Metrology (CH), Laboratoire National de Métrologie et d'Essais (FR), Baker Hughes (Germany) (DE), Safran (France) (FR)
European Commission, HORIZON EUROPE Framework Programme
Openalex Percentile: Top 27%
Advanced X-ray and CT Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.