Effect of span length and connector size on fracture resistance of monolithic zirconia FPDs: A finite element analysis

The effect of span length and connector size on the fracture resistance of monolithic zirconia fixed partial dentures (FPDs). Twelve mandibular FPD models with 3-, 4-, and 5-unit spans (9 mm, 16 mm, and 23 mm) were digitally created, each incorporating connector sizes of 12 mm<sup>2</sup>, 15 mm<sup>2</sup>, 18 mm<sup>2</sup> and 21 mm<sup>2</sup>. Finite element analysis using ANSYS 2024 simulated physiological (324 N) and maximal (1270 N) occlusal forces. Longer spans with smaller connectors generated stresses exceeding zirconia's tensile strength, while larger connectors reduced stress values significantly. Data shows that optimizing connector size is essential to improve biomechanical performance and longevity of zirconia FPDs, especially in long-span restorations.

Authors

Institutions

Publication Details

Journal
Bioinformation
Published
2025-08-31
DOI
https://doi.org/10.6026/973206300212523
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of span length and connector size on fracture resistance of monolithic zirconia FPDs: A finite element analysis

Bharti Dua, Rajiv Gupta, Cherry Anmol, Akshay Bhargava et al.
Bioinformation
Dental Implant Techniques and Outcomes
article

Effect of span length and connector size on fracture resistance of monolithic zirconia FPDs: A finite element analysis

Bharti Dua, Rajiv Gupta, Cherry Anmol, Akshay Bhargava, Mahitosh Ashokrao Lakhe, Manisha Yersong
article en

Abstract

The effect of span length and connector size on the fracture resistance of monolithic zirconia fixed partial dentures (FPDs). Twelve mandibular FPD models with 3-, 4-, and 5-unit spans (9 mm, 16 mm, and 23 mm) were digitally created, each incorporating connector sizes of 12 mm<sup>2</sup>, 15 mm<sup>2</sup>, 18 mm<sup>2</sup> and 21 mm<sup>2</sup>. Finite element analysis using ANSYS 2024 simulated physiological (324 N) and maximal (1270 N) occlusal forces. Longer spans with smaller connectors generated stresses exceeding zirconia's tensile strength, while larger connectors reduced stress values significantly. Data shows that optimizing connector size is essential to improve biomechanical performance and longevity of zirconia FPDs, especially in long-span restorations.

BioinformationVol. 21(08)
Santosh University (IN)
Openalex Percentile: Top 66%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.