Color Duplex Ultrasound Profiling of Native Hemodialysis Arteriovenous Fistula

Background Arteriovenous fistulas (AVFs) remain the preferred vascular access for hemodialysis patients due to their superior long-term patency and lower complication rates. However, AVF dysfunction due to stenosis and thrombosis remains a significant clinical challenge. Color duplex ultrasound (CDUS) has emerged as a valuable, non-invasive tool for AVF assessment, but its accuracy compared to digital subtraction angiography (DSA) remains debated. This study aims to evaluate the diagnostic reliability of CDUS in detecting AVF dysfunction and compare its findings with DSA. Methods A prospective observational study was conducted over 18 months at Shri Guru Ram Rai Institute of Medical & Health Sciences, Dehradun, including 57 hemodialysis patients undergoing AVF evaluation. CDUS parameters, including peak systolic velocity (PSV), flow volume (FV), and draining vein diameter, were assessed and compared with DSA findings. Diagnostic performance, inter-method agreement, and key hemodynamic determinants of AVF function were analyzed. Results CDUS demonstrated high sensitivity (93.35%) and specificity (92.86%) in detecting stenosis, with 100% agreement with DSA in identifying stenosis location and severity. Functional AVFs had larger draining vein diameters (6±1.1 mm vs. 2.9±0.7 mm, p=0.001) and lower FVs, emphasizing the importance of hemodynamic balance in AVF maturation. Stenotic length significantly impacted FV, with longer stenotic segments (>6 cm) associated with reduced flow (p=0.023). Conclusion CDUS is a highly accurate and non-invasive modality for AVF surveillance, demonstrating strong agreement with DSA. Given the absence of standardized Doppler criteria, further research should focus on refining hemodynamic thresholds and integrating AI-assisted ultrasound analysis for improved diagnostic precision.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-09-09
DOI
https://doi.org/10.7759/cureus.91876
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Color Duplex Ultrasound Profiling of Native Hemodialysis Arteriovenous Fistula

Sovinder Baisoya, Vivek Ruhela, Rajendra Srivastava, Sandeep Kumar et al.
Cureus
Central Venous Catheters and Hemodialysis
article

Color Duplex Ultrasound Profiling of Native Hemodialysis Arteriovenous Fistula

Sovinder Baisoya, Vivek Ruhela, Rajendra Srivastava, Sandeep Kumar, Prashant Sarda, Rohit Sharma, Kiran Shetty
article en

Abstract

Background Arteriovenous fistulas (AVFs) remain the preferred vascular access for hemodialysis patients due to their superior long-term patency and lower complication rates. However, AVF dysfunction due to stenosis and thrombosis remains a significant clinical challenge. Color duplex ultrasound (CDUS) has emerged as a valuable, non-invasive tool for AVF assessment, but its accuracy compared to digital subtraction angiography (DSA) remains debated. This study aims to evaluate the diagnostic reliability of CDUS in detecting AVF dysfunction and compare its findings with DSA. Methods A prospective observational study was conducted over 18 months at Shri Guru Ram Rai Institute of Medical & Health Sciences, Dehradun, including 57 hemodialysis patients undergoing AVF evaluation. CDUS parameters, including peak systolic velocity (PSV), flow volume (FV), and draining vein diameter, were assessed and compared with DSA findings. Diagnostic performance, inter-method agreement, and key hemodynamic determinants of AVF function were analyzed. Results CDUS demonstrated high sensitivity (93.35%) and specificity (92.86%) in detecting stenosis, with 100% agreement with DSA in identifying stenosis location and severity. Functional AVFs had larger draining vein diameters (6±1.1 mm vs. 2.9±0.7 mm, p=0.001) and lower FVs, emphasizing the importance of hemodynamic balance in AVF maturation. Stenotic length significantly impacted FV, with longer stenotic segments (>6 cm) associated with reduced flow (p=0.023). Conclusion CDUS is a highly accurate and non-invasive modality for AVF surveillance, demonstrating strong agreement with DSA. Given the absence of standardized Doppler criteria, further research should focus on refining hemodynamic thresholds and integrating AI-assisted ultrasound analysis for improved diagnostic precision.

CureusVol. 17(9)
Himalayan University (IN), Meril Life Sciences (India) (IN)
Openalex Percentile: Top 62%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.