Comparative evaluation of contrast-enhanced and time-of-flight MR venography in cerebral venous sinus thrombosis

Background and objectives Cerebral venous sinus thrombosis (CVST) is an uncommon but potentially life-threatening condition that can result in significant morbidity. Early and accurate diagnosis is essential for timely and appropriate treatment. While 2D time-of-flight (TOF) MR venography is commonly used, contrast-enhanced MR venography (CE-MRV) is often considered more accurate. This study aimed to compare the diagnostic accuracy of 2D TOF MRV and CE-MRV in detecting CVST. Materials and methods. This hospital-based ambispective study was conducted at Saveetha Medical College and Hospital, Chennai, between January 2021 and June 2022. A total of 30 patients, identified retrospectively or prospectively as clinically suspected CVST cases, were included. All patients underwent MRI and MRV using both 2D TOF and CE-MRV sequences. Sensitivity and specificity were calculated for each modality, and parenchymal changes were assessed. Results. Of the 30 patients, the majority were female (73.3%). Seizures were the most common presenting symptom (76.7%), followed by headache (73%). Superior sagittal sinus thrombosis was observed in 86% of cases. The sensitivity of 2D TOF MRV in detecting superior sagittal sinus thrombosis was 92.31%, while the sensitivity for lateral and straight sinus thrombosis was 79.17% and 100%. Conclusion. CE-MRV identified superior sagittal sinus thrombosis in 26 patients. 2D TOF MRV demonstrated a sensitivity of 92.3% and a specificity of 50% for superior sagittal sinus thrombosis, using CE-MRV as the reference standard. CE-MRV provided improved visualization of complex venous anatomy, supporting its role in accurate CVST diagnosis.

Authors

Publication Details

Journal
Romanian Medical Journal
Published
2025-09-09
DOI
https://doi.org/10.37897/rmj.2025.3.12
Primary Topic
Cerebral Venous Sinus Thrombosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of contrast-enhanced and time-of-flight MR venography in cerebral venous sinus thrombosis

Paarthipan Natarajan, Dhivya Gunasekaran, Jasvant Ram Ananthasayanam, P. Yashaswini et al.
Romanian Medical Journal
Cerebral Venous Sinus Thrombosis
article

Comparative evaluation of contrast-enhanced and time-of-flight MR venography in cerebral venous sinus thrombosis

Paarthipan Natarajan, Dhivya Gunasekaran, Jasvant Ram Ananthasayanam, P. Yashaswini, A. Tejaswin
article en

Abstract

Background and objectives Cerebral venous sinus thrombosis (CVST) is an uncommon but potentially life-threatening condition that can result in significant morbidity. Early and accurate diagnosis is essential for timely and appropriate treatment. While 2D time-of-flight (TOF) MR venography is commonly used, contrast-enhanced MR venography (CE-MRV) is often considered more accurate. This study aimed to compare the diagnostic accuracy of 2D TOF MRV and CE-MRV in detecting CVST. Materials and methods. This hospital-based ambispective study was conducted at Saveetha Medical College and Hospital, Chennai, between January 2021 and June 2022. A total of 30 patients, identified retrospectively or prospectively as clinically suspected CVST cases, were included. All patients underwent MRI and MRV using both 2D TOF and CE-MRV sequences. Sensitivity and specificity were calculated for each modality, and parenchymal changes were assessed. Results. Of the 30 patients, the majority were female (73.3%). Seizures were the most common presenting symptom (76.7%), followed by headache (73%). Superior sagittal sinus thrombosis was observed in 86% of cases. The sensitivity of 2D TOF MRV in detecting superior sagittal sinus thrombosis was 92.31%, while the sensitivity for lateral and straight sinus thrombosis was 79.17% and 100%. Conclusion. CE-MRV identified superior sagittal sinus thrombosis in 26 patients. 2D TOF MRV demonstrated a sensitivity of 92.3% and a specificity of 50% for superior sagittal sinus thrombosis, using CE-MRV as the reference standard. CE-MRV provided improved visualization of complex venous anatomy, supporting its role in accurate CVST diagnosis.

Romanian Medical JournalVol. 72(3)
Openalex Percentile: Top 65%
Cerebral Venous Sinus Thrombosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative evaluation of contrast-enhanced and time-of-flight MR venography in cerebral venous sinus thrombosis — Paarthipan Natarajan, Dhivya Gunasekaran, et al. · Romanian Medical Journal (2025) | TGRS Research Map | TGRS