On the accuracy of the standard formula for diamagnetic signal in a tokamak

Using the SPIDER code, calculations of plasma equilibrium in a tokamak with a circular plasma in a wide range of βp and ℓi (poloidal beta and internal inductance) were performed. The obtained values of the diamagnetic signal are compared with the predictions of the standard formula for tokamaks. The detected differences are analyzed using exact virial relations, an approximate consequence of which is this formula, as shown by Lao et al. [Nucl. Fusion 25, 1421 (1985)]. The reasons for the difference and the range of parameters where the accuracy of the formula is insufficient to interpret the data are identified. It is proved that the loss of accuracy in analytical theory is due to the fact that, when calculating the diamagnetic signal, only linear corrections in the inverse aspect ratio were taken into account.

Authors

Institutions

Publication Details

Journal
Physics of Plasmas
Published
2025-09-01
DOI
https://doi.org/10.1063/5.0291067
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the accuracy of the standard formula for diamagnetic signal in a tokamak

V. D. Pustovitov, А. А. Мартынов
Physics of Plasmas
Magnetic confinement fusion research
article

On the accuracy of the standard formula for diamagnetic signal in a tokamak

V. D. Pustovitov, А. А. Мартынов
article en

Abstract

Using the SPIDER code, calculations of plasma equilibrium in a tokamak with a circular plasma in a wide range of βp and ℓi (poloidal beta and internal inductance) were performed. The obtained values of the diamagnetic signal are compared with the predictions of the standard formula for tokamaks. The detected differences are analyzed using exact virial relations, an approximate consequence of which is this formula, as shown by Lao et al. [Nucl. Fusion 25, 1421 (1985)]. The reasons for the difference and the range of parameters where the accuracy of the formula is insufficient to interpret the data are identified. It is proved that the loss of accuracy in analytical theory is due to the fact that, when calculating the diamagnetic signal, only linear corrections in the inverse aspect ratio were taken into account.

Physics of PlasmasVol. 32(9)
Moscow Institute of Physics and Technology (RU), Kurchatov Institute (RU), Keldysh Institute of Applied Mathematics (RU)
Openalex Percentile: Top 90%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.