Comparative analysis of ASTM C1202 and SRPS EN 12390-18 testing methods for assessing chloride ion penetration in concrete supplemented with recycled CRT glass as cementitious material

<p>Durability is crucial for reinforced concrete, directly influencing the service life of structures. The presence of aggressive agents, especially chloride ions, significantly impacts durability. This study investigates the differences between ASTM C1202 and SRPS EN 12390-18 standards in concrete supplemented with recycled CRT glass as cementitious material. The percentage of replacement of cement with glass is: 10% and 20%, by mass. In addition to fresh state testing, the following mechanical tests were also performed: compressive strength and splitting tensile strength. The aim of this research was to determine how the addition of finely ground cathode glass affects the resistance of concrete to chloride penetration, as well as to compare the results of chloride penetration after conducting two standardized but completely different test procedures. A review of the literature revealed very few comparative tests of chloride penetration according to the mentioned standards.</p>

Authors

Institutions

Publication Details

Published
2025-09-09
DOI
https://doi.org/10.62683/sinarg2025.186
Primary Topic
Recycled Aggregate Concrete Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative analysis of ASTM C1202 and SRPS EN 12390-18 testing methods for assessing chloride ion penetration in concrete supplemented with recycled CRT glass as cementitious material

Mehmet Emiroğlu, Zoran Grdić, Dušan Grdić, Nenad Ristić et al.
Recycled Aggregate Concrete Performance
article

Comparative analysis of ASTM C1202 and SRPS EN 12390-18 testing methods for assessing chloride ion penetration in concrete supplemented with recycled CRT glass as cementitious material

Mehmet Emiroğlu, Zoran Grdić, Dušan Grdić, Nenad Ristić, Gordana Topličić–Ćurčić, S. Djoric-Veljković, Dejan Krstić
article en

Abstract

<p>Durability is crucial for reinforced concrete, directly influencing the service life of structures. The presence of aggressive agents, especially chloride ions, significantly impacts durability. This study investigates the differences between ASTM C1202 and SRPS EN 12390-18 standards in concrete supplemented with recycled CRT glass as cementitious material. The percentage of replacement of cement with glass is: 10% and 20%, by mass. In addition to fresh state testing, the following mechanical tests were also performed: compressive strength and splitting tensile strength. The aim of this research was to determine how the addition of finely ground cathode glass affects the resistance of concrete to chloride penetration, as well as to compare the results of chloride penetration after conducting two standardized but completely different test procedures. A review of the literature revealed very few comparative tests of chloride penetration according to the mentioned standards.</p>

Sakarya University (TR), University of Nis (RS)
Openalex Percentile: Top 74%
Recycled Aggregate Concrete Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.