Determination of the Transport Coefficients of an Air Plasma Contaminated by AgSnO2 Alloy Vapour

The physicochemical properties of the electric arc determine the success or failure of the electric current by the circuit breaker. This work is devoted to the determination of the transport coefficients of air plasma contaminated by silver tin(IV) oxide (AgSnO2) alloy electrical contact vapour in a low voltage circuit breaker. It aims to theoretically evaluate the influence of AgSnO2 alloy electrical contact material on the electrical current breaking capacity of the low-voltage air circuit breaker through the electrical conductivity, thermal conductivity and dynamic viscosity of the plasma air-AgSnO2. They are determined over a temperature range from 500 K –30,000 K, at atmospheric pressure and at local thermodynamic equilibrium. The analytical expressions necessary to determine these transport coefficients of the air-AgSnO2 mixture plasma are deduced from the Boltzmann equation using the approximate Chapman-Enskog method. Analyses of the obtained results show that, for the same given temperature, the electrical conductivity increases significantly when the AgSnO2 alloy vapour increases in the mixture for temperatures below 11,000 K. The dynamic viscosity of the plasma decreases as the percentage of AgSnO2 alloy electrical contact vapour increases in the mixture, for temperatures below 12,000 K. In the temperature range from 500 K–20,000 K, the total thermal conductivity of the plasma decreases as the percentage of AgSnO2 alloy electrical contact vapour increases in the mixture. It results that increasing the percentage of electrical contact vapour in AgSnO2 alloy will slow down the extinction of the electric arc created inside the circuit breaker, especially beyond 0.1% of vapour. This slowing down of the extinction of the electric arc can cause the circuit breaker to fail to cut off electrical current.

Authors

Publication Details

Journal
Journal of Physical Science
Published
2025-08-29
DOI
https://doi.org/10.21315/jps2025.36.2.1
Primary Topic
Aerosol Filtration and Electrostatic Precipitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of the Transport Coefficients of an Air Plasma Contaminated by AgSnO2 Alloy Vapour

Ibrahim Pafadnam, Yaguibou Wêpari Charles, François Zougmoré, Nièssan Kohio et al.
1 links
Journal of Physical Science
Aerosol Filtration and Electrostatic Precipitation
article

Determination of the Transport Coefficients of an Air Plasma Contaminated by AgSnO2 Alloy Vapour

Ibrahim Pafadnam, Yaguibou Wêpari Charles, François Zougmoré, Nièssan Kohio, Abdoul Karim Kagoné, Zacharie Koalaga, Adjigkiga Banouga
article en

Abstract

The physicochemical properties of the electric arc determine the success or failure of the electric current by the circuit breaker. This work is devoted to the determination of the transport coefficients of air plasma contaminated by silver tin(IV) oxide (AgSnO2) alloy electrical contact vapour in a low voltage circuit breaker. It aims to theoretically evaluate the influence of AgSnO2 alloy electrical contact material on the electrical current breaking capacity of the low-voltage air circuit breaker through the electrical conductivity, thermal conductivity and dynamic viscosity of the plasma air-AgSnO2. They are determined over a temperature range from 500 K –30,000 K, at atmospheric pressure and at local thermodynamic equilibrium. The analytical expressions necessary to determine these transport coefficients of the air-AgSnO2 mixture plasma are deduced from the Boltzmann equation using the approximate Chapman-Enskog method. Analyses of the obtained results show that, for the same given temperature, the electrical conductivity increases significantly when the AgSnO2 alloy vapour increases in the mixture for temperatures below 11,000 K. The dynamic viscosity of the plasma decreases as the percentage of AgSnO2 alloy electrical contact vapour increases in the mixture, for temperatures below 12,000 K. In the temperature range from 500 K–20,000 K, the total thermal conductivity of the plasma decreases as the percentage of AgSnO2 alloy electrical contact vapour increases in the mixture. It results that increasing the percentage of electrical contact vapour in AgSnO2 alloy will slow down the extinction of the electric arc created inside the circuit breaker, especially beyond 0.1% of vapour. This slowing down of the extinction of the electric arc can cause the circuit breaker to fail to cut off electrical current.

Journal of Physical ScienceVol. 36(2)
Openalex Percentile: Top 76%
Aerosol Filtration and Electrostatic Precipitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of the Transport Coefficients of an Air Plasma Contaminated by AgSnO2 Alloy Vapour — Ibrahim Pafadnam, Yaguibou Wêpari Charles, et al. · Journal of Physical Science (2025) | TGRS Research Map | TGRS