Mag-YOLO: Combining rotating magnetic field and improved YOLOv10 detecting for magnetic beads loading and monitoring

This work develops Mag-YOLO, a novel methodology combining rotating magnetic field and improved YOLOv10 detecting for magnetic beads loading and monitoring. By establishing a dynamic rotating magnetic field, we effectively disrupt the magnetic chains that formed by the interaction of magnetic force. The implementation of improved YOLOv10 enables real-time monitoring of magnetic magnetic beads with 98.7% detection accuracy in [email protected], a 98.3% recall rate, and 104.5 frames per second (FPS), achieving an optimal balance between real-time performance and analytical precision. The system ultimately achieved 95% loading rate within an array of 17,600 micro-wells (50 μm diameter).

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/iciea65512.2025.11148691
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mag-YOLO: Combining rotating magnetic field and improved YOLOv10 detecting for magnetic beads loading and monitoring

Zuwei Liao, Kai Hu, Yu Wang, Ming Ying
Non-Destructive Testing Techniques
article

Mag-YOLO: Combining rotating magnetic field and improved YOLOv10 detecting for magnetic beads loading and monitoring

Zuwei Liao, Kai Hu, Yu Wang, Ming Ying
article en

Abstract

This work develops Mag-YOLO, a novel methodology combining rotating magnetic field and improved YOLOv10 detecting for magnetic beads loading and monitoring. By establishing a dynamic rotating magnetic field, we effectively disrupt the magnetic chains that formed by the interaction of magnetic force. The implementation of improved YOLOv10 enables real-time monitoring of magnetic magnetic beads with 98.7% detection accuracy in [email protected], a 98.3% recall rate, and 104.5 frames per second (FPS), achieving an optimal balance between real-time performance and analytical precision. The system ultimately achieved 95% loading rate within an array of 17,600 micro-wells (50 μm diameter).

Zhejiang Police College (CN), Zhejiang University (CN)
Openalex Percentile: Top 75%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mag-YOLO: Combining rotating magnetic field and improved YOLOv10 detecting for magnetic beads loading and monitoring — Zuwei Liao, Kai Hu, et al. · (2025) | TGRS Research Map | TGRS