Neutral-Point Potential Balancing Control Method with Accurate Zero-Sequence Voltage Calculation for Common-Mode Voltage Reduction
Traditional neutral-point (NP) potential balancing control methods based on zero-sequence voltage injection require polarity determination of modulation waves for duty cycle calculation, leading to computational complexity. This paper proposes a reference voltage decomposition-based method for accurately calculating zero-sequence voltage in two-level systems to achieve NP potential balancing. The zero-sequence voltage only needs to be calculated six times based on different sectors. Furthermore, by flipping the switching sequence of one phase, common-mode voltage (CMV) reduction can be simultaneously realized, reducing the CMV amplitude to half of the original value. Experimental results validate the effectiveness of the two proposed schemes.
Authors
- Jiqiang Wang (ORCID: https://orcid.org/0000-0002-1317-0880)
- Lingfeng Meng
- Peng Gao (ORCID: https://orcid.org/0000-0003-4398-5471)
- Jingyuan Li (ORCID: https://orcid.org/0000-0003-2926-1864)
Institutions
- Inner Mongolia Electric Power (China) (CN)
Publication Details
- Published
- 2025-08-03
- DOI
- https://doi.org/10.1109/iciea65512.2025.11148444
- Primary Topic
- Multilevel Inverters and Converters
- Type
- article
- Field-Weighted Citation Impact
- 0.00