Relationship Between the Maximum Hourly Coefficient and the Design of Drinking Water Tanks in Andean Areas

Today, population growth and climate change have created major challenges to ensure a continuous supply of drinking water. Reservoir tanks regulate pressure and store drinking water according to variations in consumption. Therefore, the objective is to analyze the influence of the maximum hourly coefficient in the design of reserve tanks in the Guamote and Guano cantons. In the methodology, the maximum hourly coefficients of previous studies were validated, characteristics of the distribution networks and their tanks were compiled, drinking water levels were recorded at three times for 7 days, and finally, the design of the volume of the reserve tanks was carried out. In Guamote, water levels in the tanks range from a minimum of 38% to a maximum of 90%, while in Guano the levels are maintained at 100%, with an overflow system that evacuates excess water. In Guamote, the San Juan Bajo, San Juan Alto and Carapungo networks require regulation volumes of 257 m<sup>3</sup>, 102 m<sup>3</sup> and 61 m<sup>3</sup>, respectively. In Guano, the regulation volumes required for the La Inmaculada, Lluishi and Barrios Altos networks are 155 m<sup>3</sup>, 317 m<sup>3</sup> and 96 m<sup>3</sup>, respectively. The results indicate that higher maximum hourly coefficients are associated with higher consumption volumes, therefore, a greater volume is required in the reserve tanks.

Authors

Publication Details

Journal
Civil Engineering and Architecture
Published
2025-09-01
DOI
https://doi.org/10.13189/cea.2025.130512
Primary Topic
Oil and Gas Production Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Relationship Between the Maximum Hourly Coefficient and the Design of Drinking Water Tanks in Andean Areas

Alfonso Arellano, Lady Espinoza, M. Arias, Daniel E. Salazar et al.
Civil Engineering and Architecture
Oil and Gas Production Techniques
article

Relationship Between the Maximum Hourly Coefficient and the Design of Drinking Water Tanks in Andean Areas

Alfonso Arellano, Lady Espinoza, M. Arias, Daniel E. Salazar, María Elena Godoy Zúñiga
article en

Abstract

Today, population growth and climate change have created major challenges to ensure a continuous supply of drinking water. Reservoir tanks regulate pressure and store drinking water according to variations in consumption. Therefore, the objective is to analyze the influence of the maximum hourly coefficient in the design of reserve tanks in the Guamote and Guano cantons. In the methodology, the maximum hourly coefficients of previous studies were validated, characteristics of the distribution networks and their tanks were compiled, drinking water levels were recorded at three times for 7 days, and finally, the design of the volume of the reserve tanks was carried out. In Guamote, water levels in the tanks range from a minimum of 38% to a maximum of 90%, while in Guano the levels are maintained at 100%, with an overflow system that evacuates excess water. In Guamote, the San Juan Bajo, San Juan Alto and Carapungo networks require regulation volumes of 257 m<sup>3</sup>, 102 m<sup>3</sup> and 61 m<sup>3</sup>, respectively. In Guano, the regulation volumes required for the La Inmaculada, Lluishi and Barrios Altos networks are 155 m<sup>3</sup>, 317 m<sup>3</sup> and 96 m<sup>3</sup>, respectively. The results indicate that higher maximum hourly coefficients are associated with higher consumption volumes, therefore, a greater volume is required in the reserve tanks.

Civil Engineering and ArchitectureVol. 13(5)
Openalex Percentile: Top 70%
Oil and Gas Production Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Relationship Between the Maximum Hourly Coefficient and the Design of Drinking Water Tanks in Andean Areas — Alfonso Arellano, Lady Espinoza, et al. · Civil Engineering and Architecture (2025) | TGRS Research Map | TGRS