Evaluation of CT Image Quality Based on Signal-to-Noise Ratio in Axial and Helical Scanning Modes with Tube Current Variation

This study aims to evaluate computed tomography (CT) image quality based on the signal-to-noise ratio (SNR) parameter across two scanning modes: axial and helical. An anthropomorphic head phantom was scanned using a Siemens Healthineers Somatom go.Top CT system. The evaluation was conducted using tube current variations of 100 mAs, 200 mAs, and 300 mAs for each scanning mode. This approach was employed to investigate the influence of tube current variation on image quality and to identify the optimal parameter combination that yields the highest image quality. The results demonstrated a consistent increase in SNR with rising tube current for both scanning modes. However, the helical mode tended to produce higher SNR values compared to the axial mode at equivalent tube currents. These findings suggest that the helical mode is superior in producing better-quality images in terms of SNR. This study may serve as a reference for selecting technical imaging parameters to achieve optimal CT image quality. The conclusion indicates that the helical mode at 300 mAs provided the highest image quality, with the highest SNR value of 4.79 and the lowest noise level of 4.43 HU. Nonetheless, it should be noted that higher tube current also leads to increased radiation dose, thus clinical application should be tailored according to patient-specific needs.Keywords: CT scan, signal-to-noise ratio, image quality, axial mode, helical mode, tube current.

Authors

Publication Details

Journal
International Journal of Progressive Sciences and Technologies
Published
2025-06-16
DOI
https://doi.org/10.52155/ijpsat.v51.1.7247
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of CT Image Quality Based on Signal-to-Noise Ratio in Axial and Helical Scanning Modes with Tube Current Variation

Arnefia Mei Yusnida, Ali Khumaeni, Wahyu Setia Budi, Fitria Helmiza
International Journal of Progressive Sciences and Technologies
Advanced X-ray and CT Imaging
article

Evaluation of CT Image Quality Based on Signal-to-Noise Ratio in Axial and Helical Scanning Modes with Tube Current Variation

Arnefia Mei Yusnida, Ali Khumaeni, Wahyu Setia Budi, Fitria Helmiza
article en

Abstract

This study aims to evaluate computed tomography (CT) image quality based on the signal-to-noise ratio (SNR) parameter across two scanning modes: axial and helical. An anthropomorphic head phantom was scanned using a Siemens Healthineers Somatom go.Top CT system. The evaluation was conducted using tube current variations of 100 mAs, 200 mAs, and 300 mAs for each scanning mode. This approach was employed to investigate the influence of tube current variation on image quality and to identify the optimal parameter combination that yields the highest image quality. The results demonstrated a consistent increase in SNR with rising tube current for both scanning modes. However, the helical mode tended to produce higher SNR values compared to the axial mode at equivalent tube currents. These findings suggest that the helical mode is superior in producing better-quality images in terms of SNR. This study may serve as a reference for selecting technical imaging parameters to achieve optimal CT image quality. The conclusion indicates that the helical mode at 300 mAs provided the highest image quality, with the highest SNR value of 4.79 and the lowest noise level of 4.43 HU. Nonetheless, it should be noted that higher tube current also leads to increased radiation dose, thus clinical application should be tailored according to patient-specific needs.Keywords: CT scan, signal-to-noise ratio, image quality, axial mode, helical mode, tube current.

International Journal of Progressive Sciences and TechnologiesVol. 51(1)
Openalex Percentile: Top 77%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.