Reduced Distortion in DWI Through µs-Resolution B-Field Measurement by NeuroCam [Presidential Award Proceedings]

A field probe-equipped coil array (NeuroCam) was employed to perform dynamic, higher-order B-field-based distortion correction (DBFdc) during 12-axis DTI of ten healthy volunteers. Results obtained with and without DBFdc were compared in terms of (i) geometric congruence among the 12 axes’ diffusion-weighted images ; (ii) diffusion parameter (FA, MD, AD, RD) means within white-matter ROIs, and (iii) reproducibility of FA, MD, AD and RD means between 2 scans.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Magnetic Resonance in Medicine
Published
2025-08-15
DOI
https://doi.org/10.2463/jjmrm.2025-1838
Primary Topic
Integrated Circuits and Semiconductor Failure Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reduced Distortion in DWI Through µs-Resolution B-Field Measurement by NeuroCam [Presidential Award Proceedings]

Hiroshi Kusahara, Mizuki Akatsuka, Asao Ogawa, M. Brønsted Nielsen et al.
Japanese Journal of Magnetic Resonance in Medicine
Integrated Circuits and Semiconductor Failure Analysis
article

Reduced Distortion in DWI Through µs-Resolution B-Field Measurement by NeuroCam [Presidential Award Proceedings]

Hiroshi Kusahara, Mizuki Akatsuka, Asao Ogawa, M. Brønsted Nielsen, Tatsushi Kobayashi, Hitoshi Kanazawa, Masayuki Yamaguchi, Yoshihisa Muramatsu, Yutaka Machii
article en

Abstract

A field probe-equipped coil array (NeuroCam) was employed to perform dynamic, higher-order B-field-based distortion correction (DBFdc) during 12-axis DTI of ten healthy volunteers. Results obtained with and without DBFdc were compared in terms of (i) geometric congruence among the 12 axes’ diffusion-weighted images ; (ii) diffusion parameter (FA, MD, AD, RD) means within white-matter ROIs, and (iii) reproducibility of FA, MD, AD and RD means between 2 scans.

Japanese Journal of Magnetic Resonance in MedicineVol. 45(3)
Canon (Japan) (JP), National Cancer Center Hospital East (JP), Japan Clinical Cancer Research Organization (JP), Canon Medical Systems Corporation (Japan) (JP)
Openalex Percentile: Top 77%
Integrated Circuits and Semiconductor Failure Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reduced Distortion in DWI Through µs-Resolution B-Field Measurement by NeuroCam [Presidential Award Proceedings] — Hiroshi Kusahara, Mizuki Akatsuka, et al. · Japanese Journal of Magnetic Resonance in Medicine (2025) | TGRS Research Map | TGRS