Dynamic Operation of Battery Storage Systems for Residual Load Smoothing

Maintaining grid balance represents a significant challenge in light of the growing proportion of renewable energy sources in power generation. A viable solution to enhance grid balance is the implementation of Battery Energy Storage Systems (BESS), which can be charged during low-demand periods and discharged during peak load times. This paper investigates the feasibility of deploying a BESS within a district comprising a population of 100,000. The proposed optimization algorithm is formulated as a mixed-integer linear programming problem. While this algorithm applies a linear battery model, the results are compared to those obtained from a second-order equivalent circuit model. The findings indicate that the dynamic operation of the BESS can effectively reduce the standard deviation of the residual load by as much as 3.5 MWh.

Authors

Institutions

Publication Details

Published
2025-08-25
DOI
https://doi.org/10.1109/ccta53793.2025.11151534
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Operation of Battery Storage Systems for Residual Load Smoothing

Lingga Aksara Putra, J. Kainz, Matthias Gaderer, Jinghua Sun
Advanced Battery Technologies Research
article

Dynamic Operation of Battery Storage Systems for Residual Load Smoothing

Lingga Aksara Putra, J. Kainz, Matthias Gaderer, Jinghua Sun
article en

Abstract

Maintaining grid balance represents a significant challenge in light of the growing proportion of renewable energy sources in power generation. A viable solution to enhance grid balance is the implementation of Battery Energy Storage Systems (BESS), which can be charged during low-demand periods and discharged during peak load times. This paper investigates the feasibility of deploying a BESS within a district comprising a population of 100,000. The proposed optimization algorithm is formulated as a mixed-integer linear programming problem. While this algorithm applies a linear battery model, the results are compared to those obtained from a second-order equivalent circuit model. The findings indicate that the dynamic operation of the BESS can effectively reduce the standard deviation of the residual load by as much as 3.5 MWh.

Weihenstephan-Triesdorf University of Applied Sciences (DE), Stadtwerke Straubing (Germany) (DE)
Openalex Percentile: Top 74%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.