Mechanism of Turn-To-Turn Protection Maloperation and Anti-Maloperation Measure for HVSR

When a high-voltage shunt reactor (HVSR) is applied in a long transmission line system equipped with series compensation devices, the non-periodic components generated during fault recovery may cause maloperation of the HVSR turn-to-turn Protection Maloperation, compromising system stability and reliability. This paper investigates a busbar HVSR turn-toturn Protection Maloperation maloperation case encountered in engineering practice, studying the generation mechanism of lowfrequency current components during fault recovery. From the perspective of protection criteria, it analyzes the impact of lowfrequency components on HVSR turn-to-turn Protection Maloperation. Building upon existing protection criteria, the proposed anti-maloperation measure incorporates a Butterworth filter to process sampled signals before calculating the zerosequence power frequency components for interturn short-circuit fault discrimination. This effectively prevents protection maloperation induced by low-frequency components. The mechanism of HVSR turn-to-turn Protection Maloperation maloperation and the effectiveness of the proposed solution are validated through simulation models constructed on the PSCAD/EMTDC platform, demonstrating the technical correctness and operational effectiveness of the methodology.

Authors

Institutions

Publication Details

Published
2025-08-20
DOI
https://doi.org/10.1109/psgec66102.2025.11150807
Primary Topic
Graphite, nuclear technology, radiation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanism of Turn-To-Turn Protection Maloperation and Anti-Maloperation Measure for HVSR

Pengtao Mou, Shilin Liu, Zhijie Wang, Juan Du et al.
2 links
Graphite, nuclear technology, radiation studies
article

Mechanism of Turn-To-Turn Protection Maloperation and Anti-Maloperation Measure for HVSR

Pengtao Mou, Shilin Liu, Zhijie Wang, Juan Du, Tao Zheng, S.J. Ding
article en

Abstract

When a high-voltage shunt reactor (HVSR) is applied in a long transmission line system equipped with series compensation devices, the non-periodic components generated during fault recovery may cause maloperation of the HVSR turn-to-turn Protection Maloperation, compromising system stability and reliability. This paper investigates a busbar HVSR turn-toturn Protection Maloperation maloperation case encountered in engineering practice, studying the generation mechanism of lowfrequency current components during fault recovery. From the perspective of protection criteria, it analyzes the impact of lowfrequency components on HVSR turn-to-turn Protection Maloperation. Building upon existing protection criteria, the proposed anti-maloperation measure incorporates a Butterworth filter to process sampled signals before calculating the zerosequence power frequency components for interturn short-circuit fault discrimination. This effectively prevents protection maloperation induced by low-frequency components. The mechanism of HVSR turn-to-turn Protection Maloperation maloperation and the effectiveness of the proposed solution are validated through simulation models constructed on the PSCAD/EMTDC platform, demonstrating the technical correctness and operational effectiveness of the methodology.

Electric Power Research Institute (US), North China Electric Power University (CN), State Grid Corporation of China (China) (CN), China Power Engineering Consulting Group (China) (CN)
Openalex Percentile: Top 82%
Graphite, nuclear technology, radiation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mechanism of Turn-To-Turn Protection Maloperation and Anti-Maloperation Measure for HVSR — Pengtao Mou, Shilin Liu, et al. · (2025) | TGRS Research Map | TGRS