Two-Point Discrimination of Vibrotactile Stimuli on the Forearm MHCI032

Humans can distinguish two short simultaneous touches on the forearm, called Two-Point Discrimination (2PD), starting at a distance of approximately 40 mm. However, similar insights are lacking for vibrotactile stimuli, which would be essential for designing ergonomic gesture wristbands. Thus, an oriented 2PD test was performed using vibrotactile actuators on the forearm placed around the wrist (transverse) and along the forearm (longitudinal). The results indicate that the orientation between two actuators cannot be robustly distinguished. Two simultaneous stimuli on the forearm can best be detected at 90 mm distance, with a success rate of up to 96% for transverse placement when the actuators are arranged around the wrist. In this case, the actuators are approximately placed opposite each other, looking at the wrist as a circle. Thus, an actuator arrangement around the wrist is most sufficient to distinguish between a single and two simultaneous vibrotactile stimuli.

Authors

Institutions

Publication Details

Journal
Proceedings of the ACM on Human-Computer Interaction
Published
2025-09-09
DOI
https://doi.org/10.1145/3743721
Primary Topic
Tactile and Sensory Interactions
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-Point Discrimination of Vibrotactile Stimuli on the Forearm MHCI032

Katrin Wolf, Adrien Chaffangeon Caillet, Marco Kurzweg
Proceedings of the ACM on Human-Computer Interaction
Tactile and Sensory Interactions
article

Two-Point Discrimination of Vibrotactile Stimuli on the Forearm MHCI032

Katrin Wolf, Adrien Chaffangeon Caillet, Marco Kurzweg
article en

Abstract

Humans can distinguish two short simultaneous touches on the forearm, called Two-Point Discrimination (2PD), starting at a distance of approximately 40 mm. However, similar insights are lacking for vibrotactile stimuli, which would be essential for designing ergonomic gesture wristbands. Thus, an oriented 2PD test was performed using vibrotactile actuators on the forearm placed around the wrist (transverse) and along the forearm (longitudinal). The results indicate that the orientation between two actuators cannot be robustly distinguished. Two simultaneous stimuli on the forearm can best be detected at 90 mm distance, with a success rate of up to 96% for transverse placement when the actuators are arranged around the wrist. In this case, the actuators are approximately placed opposite each other, looking at the wrist as a circle. Thus, an actuator arrangement around the wrist is most sufficient to distinguish between a single and two simultaneous vibrotactile stimuli.

Proceedings of the ACM on Human-Computer InteractionVol. 9(5)
Berliner Hochschule für Technik (DE)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 76%
Tactile and Sensory Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.