Calculation and countermeasures of calibration error of high head multi-level ship lock water Level gauge

Abstract The accuracy of water level gauge data for high-head multi-stage ship locks is directly related to the accuracy and safety of the water conveyance control of the ship lock. The water level gauge of the ship lock is affected by the installation environment and other factors, and the water level data may deviate. During the operation of the ship lock, the water level gauge in the lock chamber will be calibrated regularly according to regulations. This article introduces the calculation and countermeasures for the calibration error of water level gauges in a high-head multi-stage ship lock, which can effectively control the errors caused by the calibration of water level gauges.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-09-01
DOI
https://doi.org/10.1088/1742-6596/3097/1/012022
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calculation and countermeasures of calibration error of high head multi-level ship lock water Level gauge

Hanlin Tan, Hang Hu, Hao Wang, Jin Xiong et al.
Journal of Physics Conference Series
Fault Detection and Control Systems
article

Calculation and countermeasures of calibration error of high head multi-level ship lock water Level gauge

Hanlin Tan, Hang Hu, Hao Wang, Jin Xiong, Daiwei Li
article en

Abstract

Abstract The accuracy of water level gauge data for high-head multi-stage ship locks is directly related to the accuracy and safety of the water conveyance control of the ship lock. The water level gauge of the ship lock is affected by the installation environment and other factors, and the water level data may deviate. During the operation of the ship lock, the water level gauge in the lock chamber will be calibrated regularly according to regulations. This article introduces the calculation and countermeasures for the calibration error of water level gauges in a high-head multi-stage ship lock, which can effectively control the errors caused by the calibration of water level gauges.

Journal of Physics Conference SeriesVol. 3097(1)
China Three Gorges University (CN)
Openalex Percentile: Top 70%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.