Interaction of intrabeam scattering, longitudinal wakefield and a passive harmonic rf cavity in SOLEIL II

Abstract Synchrotron light sources worldwide are transforming into next-generation facilities with ultra-low transverse emittances at the diffraction limits. With these parameters, intrabeam scattering (IBS) becomes significant and can spoil the light quality by increasing the natural emittance and energy spread. A harmonic cavity can be installed to mitigate this effect by increasing the bunch length. Another way to reduce the impact of IBS is to operate with the full transverse coupling. This contribution considers the IBS effect on SOLEIL II performance with an up-to-date impedance model, a passive harmonic cavity, different insertion device gap configurations (open, closed), and full transverse coupling for two main foreseen operation modes. The combined effect of IBS and microwave instability (MWI) on the energy spread is reported. It is demonstrated that the contribution of IBS to energy spread increase is as significant as that of MWI for SOLEIL II.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-09-01
DOI
https://doi.org/10.1088/1742-6596/3094/1/012030
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interaction of intrabeam scattering, longitudinal wakefield and a passive harmonic rf cavity in SOLEIL II

Alexis Gamelin, S. Habet, V. Gubaidulin, R. Nagaoka et al.
Journal of Physics Conference Series
Particle accelerators and beam dynamics
article

Interaction of intrabeam scattering, longitudinal wakefield and a passive harmonic rf cavity in SOLEIL II

Alexis Gamelin, S. Habet, V. Gubaidulin, R. Nagaoka, Laurent Nadolski, S. E. Feddaoui Dellalou
article en

Abstract

Abstract Synchrotron light sources worldwide are transforming into next-generation facilities with ultra-low transverse emittances at the diffraction limits. With these parameters, intrabeam scattering (IBS) becomes significant and can spoil the light quality by increasing the natural emittance and energy spread. A harmonic cavity can be installed to mitigate this effect by increasing the bunch length. Another way to reduce the impact of IBS is to operate with the full transverse coupling. This contribution considers the IBS effect on SOLEIL II performance with an up-to-date impedance model, a passive harmonic cavity, different insertion device gap configurations (open, closed), and full transverse coupling for two main foreseen operation modes. The combined effect of IBS and microwave instability (MWI) on the energy spread is reported. It is demonstrated that the contribution of IBS to energy spread increase is as significant as that of MWI for SOLEIL II.

Journal of Physics Conference SeriesVol. 3094(1)
Synchrotron soleil (FR)
Openalex Percentile: Top 67%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Interaction of intrabeam scattering, longitudinal wakefield and a passive harmonic rf cavity in SOLEIL II — Alexis Gamelin, S. Habet, et al. · Journal of Physics Conference Series (2025) | TGRS Research Map | TGRS