Electron beam scattering in Rubidium vapour at AWAKE

Abstract The Advanced Wakefield Experiment (AWAKE) at CERN uses bunches from the CERN SPS to develop proton-driven plasma wakefield acceleration. AWAKE Run 2c (starting in 2029) plans for external on-axis injection of a 150MeV electron witness bunch with the goal to demonstrate emittance control of multi-GeV accelerated electron beams. Prior to injection, the electron witness bunch may have to traverse rubidium vapour. Since the beam must have the correct beam size and emittance at injection, it is important to quantify the scattering effect. For this, first-principle estimates and G eant 4 simulations are compared with measurements of a ∼20MeV electron beam scattering in 5.5m of rubidium vapour, showing good agreement. Building on this agreement, G eant 4 simulations using the estimated AWAKE Run 2c parameters are performed. These predict that scattering will not increase the electron beam size or emittance.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-09-01
DOI
https://doi.org/10.1088/1742-6596/3094/1/012019
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electron beam scattering in Rubidium vapour at AWAKE

L. Ranc, M. Bergamaschi, M. Moreira, P. Muggli et al.
Journal of Physics Conference Series
Nuclear Physics and Applications
article

Electron beam scattering in Rubidium vapour at AWAKE

L. Ranc, M. Bergamaschi, M. Moreira, P. Muggli, D. Cooke, E. Gschwendtner, F. N. Pannell, M. Turner, A. Gerbershagen, J. Mezger, N. Z. van Gils
article en

Abstract

Abstract The Advanced Wakefield Experiment (AWAKE) at CERN uses bunches from the CERN SPS to develop proton-driven plasma wakefield acceleration. AWAKE Run 2c (starting in 2029) plans for external on-axis injection of a 150MeV electron witness bunch with the goal to demonstrate emittance control of multi-GeV accelerated electron beams. Prior to injection, the electron witness bunch may have to traverse rubidium vapour. Since the beam must have the correct beam size and emittance at injection, it is important to quantify the scattering effect. For this, first-principle estimates and G eant 4 simulations are compared with measurements of a ∼20MeV electron beam scattering in 5.5m of rubidium vapour, showing good agreement. Building on this agreement, G eant 4 simulations using the estimated AWAKE Run 2c parameters are performed. These predict that scattering will not increase the electron beam size or emittance.

Journal of Physics Conference SeriesVol. 3094(1)
University Medical Center Groningen (NL), University of Groningen (NL), Dialyse Centrum Groningen (NL), Max Planck Institute of Psychiatry (DE), University College London (GB), European Organization for Nuclear Research (CH)
Openalex Percentile: Top 69%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electron beam scattering in Rubidium vapour at AWAKE — L. Ranc, M. Bergamaschi, et al. · Journal of Physics Conference Series (2025) | TGRS Research Map | TGRS