Have New Plate Designs Reduced the Rate of Hardware Removal Following Midshaft Clavicle Fracture Fixation?

<b>Objectives</b>: Operative fixation of displaced midshaft clavicle fractures has become increasingly the more acceptable choice of care in recent years, based on evidence supporting its effectiveness. However, this practice presents challenges due to the complex S-shaped morphology of the clavicle and its subcutaneous location. Despite the introduction of anatomically pre-contoured plates, achieving optimal implant-to-bone fit remains difficult, prompting the development of newer plate generations. The aim of this study was to compare the hardware removal rates of second-generation 2.7 mm thinner plates (SGPs) with those of first-generation 3.5 mm plates (FGPs). <b>Methods</b>: A retrospective comparative cohort study was conducted at a level one trauma center. A total of 187 patients received FGPs, and 67 received SGPs, both positioned on the superior bone surface. All surgeries were performed by fellowship-trained surgeons, and patients were followed for at least one year. Data were extracted from medical records and the PACS system. <b>Results</b>: The patients' demographics (age: 32.86 vs. 33.14 years; gender: 16.85% vs. 14.92% female) and fracture type (AO/OTA) were similar between the two groups. The rate of implant removal (20.1% vs. 20.9%) did not differ significantly between groups. Complications included nonunion (1.6% vs. 1.7%, statistically not significant) and infection (three cases in the FGP group, none in the SGP group). <b>Conclusions</b>: Despite the high success rate of clavicle fixation procedures, the superior clavicular plate removal rate remains significant, regardless of the implant design.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-09-09
DOI
https://doi.org/10.3390/jcm14186351
Citations
1
Primary Topic
Shoulder and Clavicle Injuries
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Have New Plate Designs Reduced the Rate of Hardware Removal Following Midshaft Clavicle Fracture Fixation?

Yoram A. Weil, Omer Ben Yehuda, Rami Mosheiff, Maria Oulianski et al.
1 citations
Journal of Clinical Medicine
Shoulder and Clavicle Injuries
1.35
article

Have New Plate Designs Reduced the Rate of Hardware Removal Following Midshaft Clavicle Fracture Fixation?

Yoram A. Weil, Omer Ben Yehuda, Rami Mosheiff, Maria Oulianski, Mahmoud Jammal
article en
1 citations

Abstract

<b>Objectives</b>: Operative fixation of displaced midshaft clavicle fractures has become increasingly the more acceptable choice of care in recent years, based on evidence supporting its effectiveness. However, this practice presents challenges due to the complex S-shaped morphology of the clavicle and its subcutaneous location. Despite the introduction of anatomically pre-contoured plates, achieving optimal implant-to-bone fit remains difficult, prompting the development of newer plate generations. The aim of this study was to compare the hardware removal rates of second-generation 2.7 mm thinner plates (SGPs) with those of first-generation 3.5 mm plates (FGPs). <b>Methods</b>: A retrospective comparative cohort study was conducted at a level one trauma center. A total of 187 patients received FGPs, and 67 received SGPs, both positioned on the superior bone surface. All surgeries were performed by fellowship-trained surgeons, and patients were followed for at least one year. Data were extracted from medical records and the PACS system. <b>Results</b>: The patients' demographics (age: 32.86 vs. 33.14 years; gender: 16.85% vs. 14.92% female) and fracture type (AO/OTA) were similar between the two groups. The rate of implant removal (20.1% vs. 20.9%) did not differ significantly between groups. Complications included nonunion (1.6% vs. 1.7%, statistically not significant) and infection (three cases in the FGP group, none in the SGP group). <b>Conclusions</b>: Despite the high success rate of clavicle fixation procedures, the superior clavicular plate removal rate remains significant, regardless of the implant design.

Journal of Clinical MedicineVol. 14(18)
Hebrew University of Jerusalem (IL), Hadassah Medical Center (IL), Jerusalem Multidisciplinary College (IL)
Openalex Percentile: Top 16%
Shoulder and Clavicle Injuries
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.