Objectives: Investigate the current of injury (COI) during right ventricular lead implantation at the old patients. Methods and Results: 123 patients (pts) were implanted 2 chambers pacemaker were divided to 2 Groups. Group I included 84 pts with age < 70 years and Group II included 39 pts with age ≥ 70 years. All pts was measured the pacemaker parameters of right ventricular lead, right atrial lead and COI during lead implantation. There is not significantly different between 2 groups in the pacemaker parameter of right ventricular implantation: at sensing amplitudes (Group I were 11,18±1,92 mV vs Group II were 10,8±2 mV; p=NS); at lead impedances (Group I were 637,6±73,51 ᾨ vs Group were II 634,09±62,21 ᾨ; p=NS) and at pacing thresholds (Group I were 0,67±0,17 V vs Group II were 0,69±0,22 V; p=NS). Similar, there is not significantly different between 2 groups in the pacemaker parameter of left ventricular implantation: at sensing amplitudes (Group I were 3,23 ± 1,56 mV vs Group II were 3,15 ± 1,38 mV; p=NS); at lead impedances (Group I were 586,31 ± 125, 82 ᾨ vs Group were II 565,21 ± 137, 62 ᾨ; p=NS) and at pacing thresholds (Group I were 0,79 ± 0,14 V vs Group II were 0,76 ± 0,21 V; p=NS). Group II gets the lower of COI amplitude at right ventricular lead versus Group I (Group II were 10,81±2,31 mV vs Group I were 14,06 ± 4,13 mV; p=0,03) but no different of COI amplitude at right atrial lead between 2 Groups (Group II were 2,91 ± 0,48 mV vs Group I were 3,02 ± 0, 32 mV; p=NS) Conclusion: The patients with age ≥ 70 years get lower of COI amplitude than the patients with age < 70 years.

Authors

Institutions

Publication Details

Journal
Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt Nam
Published
2025-08-30
DOI
https://doi.org/10.47972/vjcts.v52i.1495
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of injury current amplitude in elderly patients undergoing right ventricular pacing

Nhu Hung Pham
Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt Nam
Cardiac pacing and defibrillation studies
article

Evaluation of injury current amplitude in elderly patients undergoing right ventricular pacing

Nhu Hung Pham
article en

Abstract

Objectives: Investigate the current of injury (COI) during right ventricular lead implantation at the old patients. Methods and Results: 123 patients (pts) were implanted 2 chambers pacemaker were divided to 2 Groups. Group I included 84 pts with age < 70 years and Group II included 39 pts with age ≥ 70 years. All pts was measured the pacemaker parameters of right ventricular lead, right atrial lead and COI during lead implantation. There is not significantly different between 2 groups in the pacemaker parameter of right ventricular implantation: at sensing amplitudes (Group I were 11,18±1,92 mV vs Group II were 10,8±2 mV; p=NS); at lead impedances (Group I were 637,6±73,51 ᾨ vs Group were II 634,09±62,21 ᾨ; p=NS) and at pacing thresholds (Group I were 0,67±0,17 V vs Group II were 0,69±0,22 V; p=NS). Similar, there is not significantly different between 2 groups in the pacemaker parameter of left ventricular implantation: at sensing amplitudes (Group I were 3,23 ± 1,56 mV vs Group II were 3,15 ± 1,38 mV; p=NS); at lead impedances (Group I were 586,31 ± 125, 82 ᾨ vs Group were II 565,21 ± 137, 62 ᾨ; p=NS) and at pacing thresholds (Group I were 0,79 ± 0,14 V vs Group II were 0,76 ± 0,21 V; p=NS). Group II gets the lower of COI amplitude at right ventricular lead versus Group I (Group II were 10,81±2,31 mV vs Group I were 14,06 ± 4,13 mV; p=0,03) but no different of COI amplitude at right atrial lead between 2 Groups (Group II were 2,91 ± 0,48 mV vs Group I were 3,02 ± 0, 32 mV; p=NS) Conclusion: The patients with age ≥ 70 years get lower of COI amplitude than the patients with age < 70 years.

Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt NamVol. 52
University College Hospital at Westmoreland Street (GB), University College London (GB)
Openalex Percentile: Top 63%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.